Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 115
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
Interrupted Communication between CMM
and FUC
1.
Description
The communication between CMM and FUC is interrupted.
2.
Related information
Alarm code: 0X1B27.
Alarm level: 3.
Alarm influence: The TPU polling is faulty; any data cannot be
transmitted between the TPU and CMM. The data configuration for the
FUC, CHP and CIP cannot be finished, and their statuses cannot be
reported.
Alarm unit location type: FU.
3.
Cause
The HDLC link between the OMU and the EAM is disconnected, or the
CMM hardware is in error.
4.
Handling method
The system can go on but no data configuration can be implemented.
If the long-term link disconnection occurs only to the ETRM, follow the
following steps for troubleshooting:
i.
Check whether the ETRM has been plugged or is plugged securely.
ii.
Reset the ETRM and check whether the alarm is recovered.
iii.
Check whether the CMM board works normally.
iv.
Check whether the address switches on the backplane are correct.
v.
Check whether the transmission lines on the backplane are properly
connected.
vi.
Use the HW self-loop test to judge whether it is fault with hardware
or software. If it the fault with hardware, replace the related
module. If it is the fault with software, contact the local ZTE for
handling.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.