Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 109
TPU’s FLASH MEMORY Error
1.
Description
TPU’s FLASH MEMORY is in error.
2.
Related information
Alarm code: 0X1B0E.
Alarm level: 3.
Alarm influence: The baseband processing unit cannot obtain correct
software version from the FLASH MEMORY, and the whole carrier unit
cannot work normally.
Alarm unit location type: FU
3.
Cause
The FLASH is programmed too many times, read/write error occurs, or
the software checksum is wrong.
4.
Handling method
i.
Reset the carrier unit to see whether the alarm can be recovered. If
the alarm can be recovered, it is caused by the external
interference that leads to errors when the CPU reads data from the
FLASH MEMORY. The carrier unit can work normally after the fault
is recovered.
ii.
If the resetting cannot recover the alarm, replace the ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
WATCHDOG Overflow in TPU’s CHP
DSP0
1.
Description
The WATCHDOG overflows in TPU’s CHP DSP0.
2.
Related information
Alarm code: 0X1B10.
Alarm level: 3.
Alarm influence: The DSP0 of the channel processing unit does not
respond temporarily. The control unit reloads the DSP program and re-
initializes it. If the alarm cannot be recovered, the DSP loading does
not succeed. This fault may cause two channel of a carrier unit cannot
work normally. If the carrier is a BCCH carrier, the whole cell will be
unable to work normally.
Alarm unit location type: FU