![Zte ZXG10 BS21 Maintenance Manual Download Page 120](http://html1.mh-extra.com/html/zte/zxg10-bs21/zxg10-bs21_maintenance-manual_940269120.webp)
ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
106
Confidential and Proprietary Information of ZTE CORPORATION
Alarm influence: If the ETRM with the DSP0 is the BCCH carrier, the
cell will not work normally. If not, the affected two physical channels of
the ETRM cannot work normally, but the other channels can.
Alarm unit location type: FU.
3.
Cause
DSP software or hardware is in error.
4.
Handling method
i.
Download the DSP software again.
ii.
Reset the ETRM frame and restart the DSP unit. Check whether the
alarm is recovered. If the alarm is recovered, the DSP initialization
failure is generally caused by strong external interference, and the
ETRM unit can still work normally. If the alarm cannot be recovered,
replace the corresponding ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
If the alarm affects the BCCH carrier, handle it immediately. If it
affects the TCH carrier only, handle it as soon as possible. Otherwise,
the traffic capacity of the cell will be affected.
TPU’s CHP DSP1~3 Initialization Failure
1.
Description
TPU’s CHP DSP1~3 initialization fails.
2.
Related information
Alarm code: 0X1B05, 0X1B06, 0X1B07.
Alarm level: 3.
Alarm influence: Two timeslots of the ETRM will not work normally.
That is, two physical channels of the ETRM cannot be used, which will
affect the traffic capacity of the cell.
Alarm unit location type: FU
Internal handling flow: If the BTS has another ETRM module, configure
the BCCH into another ETRM.
3.
Cause
DSP software or hardware is wrong.
4.
Handling method
i.
Download the DSP software again.
ii.
Reset the ETRM frame and restart the DSP unit. Check whether the
alarm is recovered. If the alarm is recovered, the DSP initialization