ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
110
Confidential and Proprietary Information of ZTE CORPORATION
Internal handling flow: If the BTS has other TRXs, configure the BCCH
into another TRX.
3.
Cause
The DSP0 of the channel processing unit does not respond temporarily.
4.
Handling method
i.
First reset the TRX unit to see if the alarm can be recovered. If the
alarm can be recovered, the alarm is caused by the abnormity of
the internal DSP status. The carrier unit will work normally when
the fault is recovered.
ii.
If the resetting cannot recover the alarm, have the BSC start the
BCCH changeover policy, and replace the ETRM module at the
same time.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
WATCHDOG Overflow in TPU’s CHP
DSP1~3
1.
Description
The WATCHDOG overflows in TPU’s CHP DSP1~3.
2.
Related information
Alarm code: 0X1B11, 0X1B12, 0X1B13.
Alarm level: 4.
Alarm influence: The DSP1~3 of the channel processing unit do not
respond temporarily. The control unit reloads the DSP program and re-
initializes it. If the alarm cannot be recovered, the DSP loading does
not succeed. This fault may cause two channel of a carrier unit cannot
work normally.
Alarm unit location type: FU.
Internal handling flow: If the BTS has other TRXs, configure the BCCH
into another TRX.
3.
Cause
The DSP1~3 of the channel processing unit do not respond temporarily.
4.
Handling method
i.
Reset the carrier unit and check whether the alarm can be
recovered. If the alarm can be recovered, the alarm is caused by
the abnormal internal DSP state. The carrier unit will work normally
after the reset.
ii.
If the resetting cannot recover the alarm, replace the ETRM module.
5.
Verification