ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
102
Confidential and Proprietary Information of ZTE CORPORATION
4.
Handling method
No handling is required.
5.
Verification
None.
6.
Precautions
None.
LNA (Low Noise Amplifier) Alarm
1.
Description
Overcurrent alarm happens with the LNA (low noise amplifier).
2.
Related information
Alarm code: 0X1AC8.
Alarm level: 3.
Alarm influence: the ETRM connected with it cannot work (if both the
main and diversity LNAs are faulty) or cannot work normally (if only
one LNA is faulty).
Alarm unit location type: SITE.
3.
Cause
The LNA is overcurrent by 30%.
4.
Handling method
Replace the AEM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
Power Alarm for Tower Mounted Amplifier
1.
Description
Tower amplifier power alarm happens.
2.
Related information
Alarm code: 0X1AC9.
Alarm level: 4.
Alarm influence: uplink receiving sensitivity of related ETRM is affected.
Alarm unit location type: SITE.
3.
Cause
The AEM tower amplifier power supply has an alarm. The alarm causes
should be analyzed comprehensively.
4.
Handling method