![Zte ZXG10 BS21 Maintenance Manual Download Page 106](http://html1.mh-extra.com/html/zte/zxg10-bs21/zxg10-bs21_maintenance-manual_940269106.webp)
ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
92
Confidential and Proprietary Information of ZTE CORPORATION
The red STA indicator of the CMM board does not flash at 1 Hz
frequency.
6.
Precautions
This alarm is not reported to BSC and can be viewed through the LMT.
CMM's FLASH Programming Failure
1.
Description
CMM's FLASH programming failure alarm.
2.
Related information
Alarm code: 0X1A01.
Alarm level: 3.
Alarm influence: No version can be loaded or accessed.
Alarm unit location type: SITE.
3.
Cause
The FLASH is programmed too many times and read/write error occurs.
4.
Handling method
Typically, it is the fault with the FLASH chip, and the user cannot solve
such problems. Replace the CMM module in time in the case of such
faults.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
If the CMM board is not replaced in time, the device may not be
restarted after reset.
HW Long Time Link Disconnection
1.
Description
The HW link is disconnected for a long time.
2.
Related information
Alarm code: 0X1A02.
Alarm level: 3.
Alarm influence: The site cannot work.
Alarm unit location type: SITE.
Internal handling flow: Alarm; request for soonest replacement of CMM.
3.
Cause
The inner communication in the BTS is interrupted.
4.
Handling method