Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 93
i.
Initiate the HW self-loop test flow and check whether it is the line
connection problem or the board chip fault.
ii.
If no link can be established for any ETRM, it can be considered
that the CMM module is faulty. Replace the CMM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
Power Over/Under-Voltage Alarms
1.
Description
The power supply of CMM is over/under-voltage.
2.
Related information
Alarm code: 0X1A03.
Alarm level: 3.
Alarm influence: CMM works abnormally.
Alarm unit location type: SITE
The power indicator displays the alarm.
Internal handling flow: None.
3.
Cause
The voltage of the CMM power supply is out of the adjustable range.
4.
Handling method
Replace the CMM as soon as possible.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
Clock Exceptions (13M, FCLK, SYNCLK)
1.
Description
The clock (13M, FCLK, SYNCLK) is abnormal.
2.
Related information
Alarm code: 0X1A04, 0X1A09, 0X1A0A.
Alarm level: 3.
Alarm influence: the inner transmission link of the BTS is disconnected;
the frame numbers are confusing and the frequency combiner is
abnormal.
Alarm unit location type: SITE.