Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 107
failure is generally caused by strong external interference, and the
ETRM unit can still work normally. If the alarm cannot be recovered,
replace the corresponding ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
If the alarm affects the BCCH carrier, handle it immediately. If it
affects the TCH carrier only, handle it as soon as possible. Otherwise,
the traffic capacity of the cell will be affected.
RFAD6620 Initialization Failure
1.
Description
RFAD6620 initialization fails.
2.
Related information
Alarm code: 0X1B08.
Alarm level: 3.
Alarm influence: The ETRM is unavailable. If it is a BCCH carrier, the
operation of the whole cell will be affected.
Alarm unit location type: FU
Internal handling flow: This ETRM is disabled. If it is a BCCH carrier,
implement the BCCH backup flow.
3.
Cause
AD6620 initialization fails.
4.
Handling method
i.
Reset the module to have it work normally.
ii.
If it does not work, replace the module immediately.
iii.
If the alarm persists, the E1 interface chip may be abnormal.
iv.
If the chip self-test is passed, start the E1 interface self-loop test
flow.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.