Programming
025-9368H
83
The first thing we need to do is choose three sub-audible tone/codes, one for each of our user groups.
We also need the Repeater Panel User number for each sub-audible tone/code we want to enable for
dispatch operation.
User Group
Sub-audible
Repeater Panel User #
Maintenance
127.3 Hz
(User # 20)
Manufacturing
74.4 Hz
(User # 04)
Security
D031
(User # 54)
Application Note:
The Repeater Panel User database supports 154 user groups. The sub-audible decode is pre-
determined for each user group by its corresponding user number. Users 1 to 50 are CTCSS tones,
Users 51 to 154 are DCS codes. See “CTCSS Tones” and “Digital Squelch Codes” in Section 7 to
obtain the user number for dispatch operation.
Next we need to choose Interconnect User numbers for each of our user groups. This is the ID
number that callers will use to reach a user group. This number will be overdialed for Mobile-to-
Mobile calls and Phone-to-Mobile calls. In this installation we will only be using short sign-on, user
number placement can be anywhere.
•
Maintenance
10
Dial 10 for Maintenance
•
Manufacturing
20
Dial 20 for Manufacturing
•
Security
50
Dial 50 for Security
We now have completed the necessary planning, prior to programming the Model 748 to support our
three user groups. First we will enable dispatch operation for Maintenance and Security in the
Repeater Panel User database. Next we will program the Interconnect User database to support short
sign-on.
To enable the Maintenance user group for dispatch operation on 127.3 Hz, select User range and set
the range to “20”. Verify that Decode is “127.3”. Set Enabled to “Yes”.
REPEATER PANEL USER MENU
1 - User range: 20
8 - Courtesy bip: Disabled
2 -
Enabled: Yes
9 - Hog mode: Disabled
3 - Decode: 127.3
10 - DTMF Repeat: Disabled
4 - Encode: 127.3
11 - Morse ID:
5 - Reserved: Disabled
12 - Tx hold time: 2000 msecs
6 - Privacy: Disabled
13 - List users (in user range)
7 - Encode during TX hold: No
14 - Airtime - Accumulate: 00:00:00
<ESC> to exit
Select a command:
To enable the Security user group on D031 select User range and set the range to “54”. This selects
the Repeater Panel User number corresponding to D031. Verify that Decode is “D031”. Set Enabled
to “Yes”.
We now have CTCSS tone 127.3 Hz and DCS code D031 enabled for dispatch operation.
Summary of Contents for 748
Page 2: ......
Page 68: ...Operation 54 025 9368H Notes...
Page 110: ...Programming 96 025 9368H Notes...
Page 216: ...Feature Set Reference 202 025 9368H Notes...
Page 219: ...Repair 025 9368H 205 MODEL 7XX AUDIO BLOCK DIAGRAM 006 0077A...
Page 225: ...Repair 025 9368H 211 MODEL 7XX CONTROL BOARD 008 9793D Schematic Sheet 1 of 5...
Page 226: ...Repair 212 025 9368H MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 2 of 5...
Page 227: ...Repair 025 9368H 213 MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 3 of 5...
Page 228: ...Repair 214 025 9368H MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 4 of 5...
Page 229: ...Repair 025 9368H 215 MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 5 of 5...
Page 230: ...Repair 216 025 9368H MODEL 7XX CONTROL BOARD 702 9793D Silkscreen...
Page 233: ...Repair 025 9368H 219 MODEL 7XX SINGLE E E CARD 008 9794A Schematic...
Page 234: ...Repair 220 025 9368H MODEL 7XX SINGLE E E CARD 702 9794A Silkscreen...
Page 236: ...Repair 222 025 9368H MODEL 4XB VOICE CARD 008 9236F Schematic...
Page 237: ...Repair 025 9368H 223 MODEL 4XB VOICE CARD 702 9236F Silkscreen...
Page 239: ...Repair 025 9368H 225 MODEL 4XB DIAL CLICK BOARD 008 9242E Schematic...
Page 240: ...Repair 226 025 9368H MODEL 4XB DIAL CLICK BOARD 702 9242E Silkscreen...
Page 254: ...Quick Reference 240 025 9368H Notes...
Page 258: ...Specifications 244 025 9368H...
Page 259: ...Specifications 025 9368H 245...