Product Description
ACCESSORIES AND OPTIONS
POWER OPTIONS
COMPRESSOR POWER CONNECTION –
Single-
point (YCAL0019-0066) terminal block connection is
provided as standard. The following power connections
are available as options. (See electrical data for speci
fi
c
voltage and options availability) (
Factory-Mounted
).
SINGLE-POINT SUPPLY TERMINAL BLOCK
–
(standard on YCAL0019 – 0066 models) Includes
enclosure, terminal-block and interconnecting wiring to
the compressors. Separate external protection must be
supplied, by others, in the incoming compressor-power
wiring. (Do not include this option if either the Single-
Point Non-fused Disconnect Switch or Single-Point
Circuit Breaker options have been included).
SINGLE-POINT NON-FUSED DISCONNECT
SWITCH –
Unit-mounted disconnect switch with
external, lockable handle (in compliance with Article
440-14 of N.E.C.), can be supplied to isolate the unit
power voltage for servicing. Separate external fusing
must be supplied, by others in the power wiring, which
must comply with the National Electrical Code and/or
local codes.
SINGLE-POINT CIRCUIT BREAKER –
A unit
mounted circuit breaker with external, lockable handle
(in compliance with N.E.C. Article 440-14), can be
supplied to isolate the power voltage for servicing (this
option includes the Single-Point Power connection).
CONTROL TRANSFORMER –
Converts unit power
voltage to 115-1-60 (0.5 or 1.0 KVA capacity). Fac-
tory mounting includes primary and secondary wiring
between the transformer and the control panel (
Fac-
tory-Mounted
).
POWER FACTOR CORRECTION CAPACITORS
–
Will correct unit compressor power factors to a 0.90-
0.95 (
Factory-Mounted
).
CONTROL OPTIONS
AMBIENT KIT (LOW) –
Units will operate to 25 °F (-
4 °C). This accessory includes all necessary components
to permit chiller operation to 0 °F (-18 °C). (This option
includes the Discharge Pressure Transducer / Readout
Capability option). For proper head pressure control
in applications below 25 °F (-4 °C), where wind gusts
may exceed
fi
ve mph, it is recommended that Optional
Condenser Louvered Enclosure Panels also be included
(
Factory-Mounted
).
AMBIENT KIT (HIGH) –
Required if units are to
operate when the ambient temperature is above 110 °F
(43 °C). Includes discharge pressure transducers. (This
option includes the Discharge Pressure Transducer /
Readout Capability option) (
Field-Mounted
).
BUILDING AUTOMATION SYSTEM INTER-
FACE –
The factory addition of a Printed Circuit Board
to accept a 4-20 milliamp, 0-10VDC or contact closure
input to reset the leaving chiller liquid temperature from
a Building Automation System. (Only one of following
options can be offered on a unit at a time: BAS, Remote
Control Panel or Multi-unit Sequence Control) (
Fac-
tory-Mounted
). (The standard unit capabilities include
remote startstop, remote water temperature reset via a
PWM input signal or up to two steps of demand (load)
limiting depending on model). (The standard control
panel can be directly connected to a YORK Building
Automated System via the standard onboard RS485
communication port).
LANGUAGE LCD AND KEYPAD DISPLAY –
Span-
ish, French, and German unit LCD controls and keypad
displays are available. Standard language is English.
DISCHARGE PRESSURE TRANSDUCERS AND
READOUT CAPABILITY –
The addition of pressure
transducers allows models to sense and display discharge
pressure. This is recommended for brine chilling appli-
cations. (This option is included with either the low or
high ambient kits) (
Factory-Mounted
).
•
Suction Pressure Transducers
: Permits unit to
sense and display suction pressure. This capability
is standard on YCAL0019-0066 models.
MOTOR CURRENT MODULE –
Capable of moni-
toring compressor motor current. Provides extra protec-
tion against compressor reverse rotation, phase-loss and
phase imbalance. Option consists of one module per
electrical system (
Factory-Mounted
).
MULTI-UNIT SEQUENCING –
A separate Sequenc-
ing Control Center can be provided to handle sequencing
control of up to eight chillers in parallel based on mixed
liquid temperature (interconnecting wiring by others).
(Only one of following options can be offered on a unit
at a time: BAS, Remote ControSl Panel or Multi-unit
Sequence Control) (
Factory-Mounted
).
Summary of Contents for YCAL0019
Page 55: ...FORM 150 67 NM2 209 55 JOHNSON CONTROLS 5 5 ELEMENTARY WIRING DIAGRAM CON T LD12699D...
Page 57: ...FORM 150 67 NM2 209 57 JOHNSON CONTROLS 5 5 ELEMENTARY WIRING DIAGRAM CON T LD12693C...
Page 59: ...FORM 150 67 NM2 209 59 JOHNSON CONTROLS 5 5 ELEMENTARY WIRING DIAGRAM CON T LD 12198...
Page 61: ...FORM 150 67 NM2 209 61 JOHNSON CONTROLS 5 5 LD12702 ELEMENTARY WIRING DIAGRAM CON T...
Page 63: ...FORM 150 67 NM2 209 63 JOHNSON CONTROLS 5 5 LD12696 ELEMENTARY WIRING DIAGRAM CON T...
Page 65: ...FORM 150 67 NM2 209 65 JOHNSON CONTROLS 5 5 CONNECTION WIRING DIAGRAM CON T LD12703B...
Page 67: ...FORM 150 67 NM2 209 67 JOHNSON CONTROLS 5 5 CONNECTION WIRING DIAGRAM CON T LD12697B...