5-34
SM-16005-rev.2
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
(102) Not Prepared (LA)
(103) Not Prepared (Lb)
(104) Setting Temperature (P1)
This function is utilized to provide setting temperature for every 1
o
F (0.5
o
C) at "00" and every 2
o
F (1
o
C)
at "01".
Control differential of thermistor also uses the temperature for every 1
o
F (0.5
o
C) at "00" and every 2
o
F
(1
o
C) at "01".
(105) Not Prepared (P2)
(106) Thermistor Selection (P3)
This function is utilized to select the thermistor with function (107).
(93) Not Prepared (L1)
(94) Not Prepared (L2)
(95) Not Prepared (L3)
(96) Not Prepared (L4)
(97) Not Prepared (L5)
(98) Not Prepared (L6)
(99) Not Prepared (L7)
(100) Not Prepared (L8)
(101) Auxiliary Heater OFF at Defrost Operation (L9)
This function is utilized to activate/deactivate heater during defrost operation when heater operation is
enabled.
The setting conditions and the heater during defrost are as follows:
Setting Condition
Thermistor (Sensor)
00
Inlet Air Thermistor
01
Outlet Air Thermistor
02
Thermistor of Remote Control
03
Remote Sensor
(107) Display of Thermistor Temperature (P4)
This function is utilized to display the temperature of the sensor selected at (106).
(108) Setting Temperature Display during Fan Operation (P5)
This function is utilized to undisplay the setting temperature during fan mode operation.
(109) ECO Button Operation (P6)
This function is prohibiting "ECO" button operation by setting at "01"
(110) Menu Button Operation (P7)
This function is utilized to invalidate the menu button.
(111) Not Prepared (P8)
(112) Not Prepared (P9)
(113) Not Prepared (PA)
(114) Not Prepared (Pb)
(115) Not Prepared (PC)
Setting Condition
Heater during Defrost
Fan Operation
00
ON
SLOW
01
OFF
STOP
Summary of Contents for IDM030B21E Series
Page 2: ......
Page 10: ...viii SM 16005 rev 2...
Page 14: ......
Page 15: ...SM 16005 rev 2 1 1 INSTALLATION 1 Installation...
Page 19: ...SM 16005 rev 2 2 1 OPERATION 2 Operation...
Page 22: ......
Page 23: ...SM 16005 rev 2 3 1 TROUBLESHOOTING 3 Troubleshooting...
Page 70: ......
Page 71: ...SM 16005 rev 2 4 1 MAINTENANCE 4 Maintenance...
Page 130: ......
Page 131: ...SM 16005 rev 2 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions...
Page 140: ...6 10 SM 16005 rev 2 FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A f t 3 l b...
Page 141: ...SERVICE PARTS LIST SM 16005 rev 2 7 1 7 Service Parts List...
Page 143: ......
Page 144: ...2016 Johnson Controls Inc SM 16005 rev 2 Code No LIT 12012293 Revised February 2019...