4-4
IM WT5000-01EN
Display Format of External Current Sensor Range (Ext Sensor
Range Display Format)
You can select the external current sensor range display format from the following options.
• Direct input value display (Direct)
Values are displayed within the external current sensor range (voltage). This setting is useful when you want
to set the external current sensor range using the voltage received by this instrument from the external current
sensor as a guide.
• Measurement range display (Measure)
The external current sensor range is divided by the external current sensor conversion ratio, and the resulting
(current) range is displayed. This setting is useful when you want to set the external current sensor range
using the current measured by the external current sensor as a guide. For example, if you are using a current
sensor that produces 10 mV when it receives 1 A (external current sensor conversion ratio: 10 mV/A) and you
set the external current sensor range to 1 V, the displayed current range is 100 A.
4 Input Settings (Advanced/Options)