14-23
IM 760401-01E
Communication Commands 2 (System of Commands Complying to the IEEE 488.2-1992 Standard)
14
DISPlay<x>:RESolution
Function
Sets the number of displayed digits/queries the
current setting.
Syntax
DISPlay<x>:RESolution {HIGH|Low}
DISPlay<x>:RESolution?
<x>= 1 to 3
1:Display A
2:Display B
3:Display C
Example
DISPLAY1:RESOLUTION LOW
DISPLAY1:RESOLUTION? -> :DISPLAY1:
RESOLUTION LOW
Description <x> will be ignored. The contents of all the
displays A to C will be received.
DISPlay<x>:FUNCtion
Function
Sets the function to be displayed/queries the
current setting.
Syntax
DISPlay<x>:FUNCtion {<display
function>}
DISPlay<x>:FUNCtion?
<x>= 1 to 3
1:Display A
2:Display B
3:Display C
In case of normal measurement:
<display function>={V|A|W|VA|VAR|PF|
DEGRee|VHZ|AHZ|WH|WHP|WHM|AH|AHP|AHM|
MATH|VPK|APK|TIME}
In case of harmonic measurement:
<display function>={V|A|W|PF|VHZ|AHZ|
VTHD|ATHD|VCON|ACON|WCON|VDEG|ADEG|
ORDer}
Example
DISPLAY1:FUNCTION V
DISPLAY1:FUNCTION? -> :DISPLAY1:
FUNCTION V
Description For the meanings of the symbols of functions,
see Note on page 14-14.
DISPlay<x>:MODE
Function
Sets the contents of the display/queries the
current setting.
Syntax
DISPlay<x>:MODE {VALue|
RANGe|ESCaling}
DISPlay<x>:MODE?
<x>= 1 to 3
1:Display A
2:Display B
3:Display C
VALue: displays measurement data
RANGe: displays the present range of
voltage and current, or the scaling
values of the external sensor of
element 1.
ESCaling: displays the scaling values
of the current external sensor
Example
DISPLAY1:MODE VALUE
DISPLAY1:MODE? -> :DISPLAY1:
MODE VALUE
Description <x> will be ignored. The contents of all the
displays A to C will be received.
14.3 Commands
Summary of Contents for WT210
Page 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Page 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Page 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Page 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Page 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...