• dFLt-i (integration measurement values are set as default)
Select this when you want to output integration measurement values. Which items
are output to which channel is described below.
Option
Model
ch1
ch2
ch3
ch4
ch5
ch6
ch7
ch8
ch9
ch10
ch11
ch12
/DA4
760401
/DA12
/CMP
760502
760503
760401
760502
760503
W
Wh
Ah
Hz
W1
-
W3
Σ
W
Wh1
-
Wh3
Σ
Wh
Ah1
-
Ah3
Σ
Ah
W1
W2
W3
Σ
W
Wh1
Wh2
Wh3
Σ
Wh
Ah1
Ah2
Ah3
Σ
Ah
W
Wh
Ah
Hz
These
channels
cannot be
set.
These channels cannot be set.
*1
*1
*1
*2
If either one of the display function, V Hz or A Hz, is turned on, the frequency of the
corresponding function is output. If both display functions are OFF, the voltage frequency
of the element assigned to display C is output.
The number corresponds to input element 1, 2, or 3.
*2
*2
W1
Wh1
Ah1
Hz
*1
W1
Wh1
Ah1
Hz
*1
*2
*2
Output
channel
Setting an Original Output Format
The items to be output (output function and element) are set per each output channel.
• Setting the output channel
The number of channels depends on the installed options and can be selected
from the following.
• /DA4: 4 channels
• /DA12: 12 channels
• /CMP: 4 channels
• Setting the output function (corresponds to column A in the procedure)
The output function can be set to any of the following.
V (voltage), A (current), P (active power), VAr (reactive power), VA (apparent
power), PF (power factor), VFrq (voltage frequency
*1
), AFrq (current frequency
*1
),
Ph (total Watt-hour Wh), Ah (total Ampere-hour), dEG (phase angle), VP (peak
value of voltage), AP (peak value of current), MATH (computation), Ph+ (positive
watt hour value Wh+), Ph– (negative watt hour value Wh–), Ah+ (positive ampere
hour value
*2
), Ah– (negative ampere hour value
*2
), – – – – – – (D/A output 0 V; no
further elements can be set)
*1 If either one of the display function, V Hz or A Hz, is turned on, the frequency of
the corresponding function is output. If both display functions are OFF, the
voltage frequency of the element assigned to display C that was illuminated last
when display function V Hz or A Hz was illuminated is output.
*2 For details concerning the positive value of the ampere hour, refer to page 6-3.
• Setting the element (corresponds to colum B in the procedure)
• WT210 (760401) no such element setting available;
• WT230 (760502) element can be selected from 1, 3, or 4
• WT230 (760503) element can be selected from 1, 2, 3, or 4
The element number 4 represents
Σ
.
9.3 D/A Output (Option)
Summary of Contents for WT210
Page 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Page 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Page 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Page 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Page 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...