14-13
IM 760401-01E
Communication Commands 2 (System of Commands Complying to the IEEE 488.2-1992 Standard)
14
Command
Description
Page
:MEASure[:NORMal]:ITEM:{TIME|MATH}
Sets/queries the ON/OFF state of the communication output of
{integration time|MATH}
.
14-31
:MEASure[:NORMal]:ITEM:<normal measurement function>?
Queries communication output settings of the normal measurement function. 14-31
:MEASure[:NORMal]:ITEM:<normal measurement function>[:ALL]
Sets the communication output items concerning all elements or S ON/
OFF at once.
14-31
:MEASure[:NORMal]:ITEM:<normal measurement function>:ELEMent<x>
Sets/queries the communication output items concerning each element
ON/OFF.
14-31
:MEASure[:NORMal]:ITEM:<normal measurement function>:SIGMa
Sets/queries the communication output items concerning S ON/OFF.
14-31
:MEASure[:NORMal]:VALue?
Queries normal measured/computed data set by commands other than
“
MEASure[:NORMal]:ITEM
” (ASCII format).
14-31
RECall Group
:RECall?
Queries all settings related to recalling data.
14-36
:RECall:INTerval
Sets/queries the recalling interval.
14-36
:RECall:PANel
Retrieves the setup parameters file.
14-36
:RECall[:STATe]
Sets/queries recalling ON/OFF.
14-36
RELay Group
:RELay?
Queries all settings related to the comparator function.
14-37
:RELay:DISPlay
Sets/queries the comparator display OFF, or in case of ON, the channel
to be displayed.
14-37
:RELay:HCHannel<x>?
Queries all settings related to relay output items in case of harmonic
measurement.
14-37
:RELay:HCHannel<x>:FUNCtion
Sets/queries function of the relay output item in case of harmonic measurement. 14-38
:RELay:HCHannel<x>:THReshold
Sets/queries the threshold level for the relay output item.
14-38
:RELay:MODE
Sets/queries the mode of the comparator function.
14-38
:RELay:NCHannel<x>?
Queries all settings related to the relay output items in case of normal
measurement.
14-38
:RELay:NCHannel<x>:FUNCtion
Sets/queries the function of the relay output in case of normal
measurement.
14-38
:RELay:NCHannel<x>:THReshold
Sets/queries the threshold level for the relay output item.
14-38
:RELay[:STATe]
Sets/queries the comparator function ON/OFF.
14-38
SAMPle Group
:SAMPle?
Queries all settings related to sampling.
14-39
:SAMPle:HOLD
Sets/queries to hold the output of data (display, communication).
14-39
:SAMPle:RATE
Sets the display update rate or queries the current setting.
14-39
STATus Group
:STATus?
Queries all settings related to the status of communication.
14-40
:STATus:CONDition?
Queries the contents of the condition filter.
14-40
:STATus:EESE
Sets/queries the extended event register.
14-40
:STATus:EESR?
Queries the contents of the extended event register and clears it.
14-40
:STATus:ERRor?
Queries the occurred error code and message.
14-40
:STATus:FILTer<x>
Sets/queries the transit filter.
14-40
:STATus:QMESsage
Sets/queries whether or not to apply the corresponding message to the
query “
STATus:ERRor?
”.
14-41
:STATus:SPOLl?(Serial Poll)
Executes serial polling.
14-41
14.3 Commands
Summary of Contents for WT210
Page 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Page 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Page 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Page 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Page 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...