IM 701210-07E
46
Setup Menu Items
GO/NO-GO determination mode
Section 11.8
Select the measured values of waveform
parameters (Parameter).
Determination condition
Set the target waveform, determination criteria,
parameter, upper and lower limits of the
parameter, action conditions, etc.
Action after determination
Select printing of the screen image (PRINT),
saving of the screen image data (Image),
saving of the waveform data (Save to File),
beep sound (Buzzer), or mail transmission
(Send Mail).
Determination range
Set the determination start point and
determination end point when limiting the
range along the time axis where determination
is performed.
Execute the determination
Types of GO/NO-GO Determination Mode
This function is useful when you want to inspect signals
and track down abnormal symptoms on a production
line making electronic equipment. The function
determines whether the waveform is within the preset
range and performs a predetermined action when the
decision is GO (or NO-GO). There are two types of
determinations.
• Parameter
By setting the upper/lower limits of the automated
measurement of waveform parameters, GO/NO-GO
determination is performed on whether the measured
value enters the range or exits the range.
• Zone
GO/NO-GO is determined by creating a zone based
on a reference waveform and checking whether or not
the waveform has left or entered the zone.
Note
• The following figure shows the menu that appears when the GO/NO-GO determination mode is set to the measured
values of waveform parameters.
GO/NO-GO determination mode
Section 11.9
Select the waveform zone (Zone).
Creating the determination zone
Select the basic waveform, create/edit the
determination zone, and register zones.
Determination condition
Set the target waveform, determination criteria,
zone number, determination logic, action
condition, etc.
Action after determination
Select printing of the screen image (PRINT),
saving of the screen image data (Image),
saving of the waveform data (Save to File),
beep sound (Buzzer), or mail transmission
(Send Mail).
Determination range
Set the determination start point and
determination end point when limiting the
range along the time axis where determination
is performed.
Execute the determination
• The following figure shows the menu that appears when the GO/NO-GO determination mode is set to waveform zone.
+