7-26
IM CW120-E
7.2.15 Selecting Clamp-on Current Probe to Be Used (
)
Description
The following four models of clamp-on current probes can be connected to
the CW120/121.
Selectable Clamp-on Current Probes
Clamp-on Current Probe Model
96033
96030
96031
96032
Setting
50 A
200 A
500 A
1000 A
Rating (Ranges)
5/10/20/50 A
2/50/100/200 A
50/100/200/500 A
200/500/1000 A
Default: 200 A
Procedure
(1) Using the
keys, make the
mark (in the lower right) and its
current setting appear on the screen. Then, press the
key. The
number representing the currently selected clamp model flashes.
Selecting Clamp-on Current Probe to Be Used
DISP
ENTER
MEAS/SET
ESC
MEAS/SET key
UP/DOWN/LEFT/RIGHT keys
ENTER key
ESC key
(2) Using the
keys, select the number corresponding to the
desired clamp-on current probe. The number changes sequentially as
follows.
or
or
7.2 Setting Each Item