9-15
IM CW120-E
Electric Energy Measurement
9
9.5
Backup Memory
The CW120/121 have a built-in memory for backing up the PC card and can
be used for saving data up to 3000 times. Data is saved to the backup
memory in the following cases:
• When the PC card becomes full (the
mark appears).
• The PC card is removed during integration.
When data resides in the backup memory, the
mark is displayed. (The
data stored in the backup memory is retained during power-off.)
The data in the backup memory is cleared whenever integration starts.
Namely, starting integration when previous data is retained in the backup
memory deletes it.
NOTE
When an attempt is made to save data to the backup memory more than 3,000 times,
appears and the saving action is aborted.
The data in the backup memory is processed as follows.
●
When a PC Card Having Sufficient Free Space Is Inserted during
Integration
When a PC card is inserted, the data from that time on is saved to the PC
card with the same file name as before. Then, when integration ends, the
data stored in the backup memory will be copied to the bottom of the last
file (i.e., data is added within the last file) in the PC card. During this
copying action,
is displayed on the screen and it will change
to
, indicating that integration has ended.
Removing
Inserting
Copy
PC card that has become full
New PC card
Data file AWTH005.CSV
CW120
Backup memory
File name:
AWTH005.CSV
File name:
AWTH005.CSV
File name:
AWTH005.CSV
Integrated data