2-8
IM CW120-E
●
Indications of Setting Items
Mark appearing during setting mode:
Setting Item
Displayed Mark
1.
Device number
2.
Loading and saving of settings
3.
Deletion of measured-data file and formatting of PC card
4.
Clearance of electric energy count (watt-hours) and resetting of system
5.
Copying and clearance of backup memory
6.
Date
7.
Output interval
8.
Integration start date and time
9.
Integration stop date and time
10. Whether to save data to PC card
11. Selection of communication device
12. Communication settings
13. VT ratio setting
14. CT ratio setting
15. Probe selection
16. Decimal position and unit selections for electric energy (watt-hours)
●
Indications during Measurement
Displayed Mark
Lights when integration is carried out; flashes when integration is on stand-
by.
Lights when integration is controlled by external signals.
Lights when PC card memory is full.
Lights when the backup memory contains data.
Lights when the battery voltage is low.
Lights when the keys are locked.
Lights when data saving to the PC card is enabled; flashes during access
to the PC card.
Flashes during access to the PC when a PC is selected as the
communication device.
Flashes during access to the printer when a printer is selected as the
communication device.
Lights when the VT ratio is set at a value other than 1.
Lights when the CT ratio is set at a value other than 1.
Indications for current settings of voltage range, current range, and wiring
method:
Wiring method
Voltage range
Current range
2.4 Overrange and Other Marks Shown during Measurement