16-8
IM 765501-01E
Command
Function
Page
:SPACing?
Queries the sweep mode (linear or log) of the current sweep.
16-21
:STARt <Current>|MINimum|MAXimum
Sets the start value of the current sweep.
16-21
:STARt? [MINimum|MAXimum]
Queries the start value of the current sweep.
16-21
:STOP <Current>|MINimum|MAXimum
Sets the stop value of the current sweep.
16-22
:STOP? [MINimum|MAXimum]
Queries the stop value of the current sweep.
16-22
:STEP <Current>|MINimum|MAXimum
Sets the step value of the current sweep (linear sweep).
16-22
:STEP? [MINimum|MAXimum]
Queries the step value of the current sweep (linear sweep).
16-22
:POINts <Integer>|MINimum|MAXimum
Sets the step count of the current sweep (log sweep).
16-22
:POINts? [MINimum|MAXimum]
Queries the step count of the current sweep (log sweep).
16-22
:ZERO
:IMPedance HIGH|LOW
Sets the zero source impedance (high or low) for generating current.
16-22
:IMPedance?
Queries the zero source impedance (high or low) for generating current.
16-22
:OFFset <Current>
Sets the zero source offset value for generating current.
16-22
:OFFset?
Queries the zero source offset value for generating current.
16-22
Sweep Commands (SWEep Group)
:SWEep
:TRIGger
Starts the sweep operation.
16-23
:COUNt <Integer>|INFinity|MINimum|MAXimum
Sets the sweep repeat count.
16-23
:COUNt? [MINimum|MAXimum]
Queries the sweep repeat count.
16-23
:LAST KEEP|RETurn
Sets the sweep termination mode (keep level or return to initial level).
16-23
:LAST?
Queries the sweep termination mode (keep level or return to initial level).
16-23
Measurement Commands (SENSe Group)
:SENSe
[:STATe] 1|0|ON|OFF
Sets the measurement state (ON or OFF).
16-24
[:STATe]?
Queries the measurement state (ON or OFF).
16-24
:FUNCtion VOLTage|CURRent|RESistance
Sets the measurement function (voltage, current, or resistance).
16-24
:FUNCtion?
Queries the measurement function (voltage, current, or resistance).
16-24
:RANGe
:AUTO 1|0|ON|OFF
Sets the measurement auto range (ON or OFF).
16-24
:AUTO?
Queries the measurement auto range (ON or OFF).
16-24
:ITIMe <Time>|PLC|MINimum|MAXimum|UP|DOWN
Sets the integration time.
16-24
:ITIMe? [PLC|MINimum|MAXimum]
Queries the integration time.
16-24
:DELay <Time>|MINimum|MAXimum
Sets the measurement delay.
16-24
:DELay? [MINimum|MAXimum]
Queries the measurement delay.
16-24
:AZERo
[:STATe] 1|0|ON|OFF
Sets the auto zero state (ON or OFF).
16-25
[:STATe]?
Queries the auto zero state (ON or OFF).
16-25
:EXECute
Executes auto zero.
16-25
:AVERage
[:STATe] 1|0|ON|OFF
Sets the average state (ON or OFF).
16-25
[:STATe]?
Queries the average state (ON or OFF).
16-25
:MODE BLOCk|MOVing
Sets the average mode (block or moving average).
16-25
:MODE?
Queries the average mode (block or moving average).
16-25
:COUNt <Integer>|MINimum|MAXimum
Sets the average count.
16-25
16.2 Commands