2 Module Specifications
2.2.2 Module Configuration Definitions
2-8
2.2.2 Module Configuration Definitions
Configuration of the MP2300 including Basic Module and Optional Modules can be obtained and modified in the
Module Configuration
Window.
( 1 ) Module Configuration Window Components
A typical MP2300 Module Configuration Window is shown below.
For information on how to open the Module Configuration Window, refer to
4.3.2 ( 4 ) Set and Save Motion Fixed
Parameters
on page 4-36.
The following table lists the items shown in the Module Configuration Window.
Configuration of the Basic
Module CPU
Configuration of the CPU I/O
Module built in the Basic Module
Configuration of the SVB
Module built in the Basic Module
Configuration of the SVR Virtual
Motion Module built in the Basic
Module
Information on Basic Module Information on the mounted Optional Modules
Item
Description
Modification
Slot Number
Slot number
Not possible
Module Type
Module detected in the slot
Possible
Controller Number
Fixed to 01
Not possible
Circuit Number
Module circuit number
Possible
I/O Start Register
I/O start register number of the I/O Module to be connected to
MECHATROLINK
Possible
I/O End Register
I/O last register number of the I/O Module to be connected to
MECHATROLINK
Possible
Disable Input
Input enabled (Enable)/disabled (Disable)
Possible
(Not possible
if the cell is
blank)
Disable Output
Output enabled (Enable)/disabled (Disable)
Possible
(Not possible
if the cell is
blank)
Motion Start Register
Start register number of the motion parameters
(Automatically sets according to the circuit number)
Not possible