5.4 Self-configuration
5-33
5
Outline of Motion Control Systems
2.
Select
Order - Self Configure All Modules
from the main menu to execute self-configuration.
The RUN LED indicator will blink and a message indicating that
the module configuration definitions are being
created
will be dispayed. Once self-configuration has been completed, the message will disappear and the RUN
LED indicator will return to its original state.
3.
Select
File - Save & Save to FLASH
to save the definitions data to the flash memory.
4.
Right-click the
No. 3
colum in the Module Details area and click
MECHATROLINK
on the pop-menu
that appears.
The
MECHATROLINK
Window will appear.