Figure 2.70 Offset Frequency Operation
■
d7-01: Offset Frequency 1
No.
(Hex.)
Name
Description
Default
(Range)
d7-01
(02B2)
RUN
Offset Frequency 1
Uses
H1-xx = 44 [MFDI Function Select = Add Offset Frequency 1 (d7-01)]
as a percentage of the
Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.
0.0%
(-100.0 - +100.0%)
■
d7-02: Offset Frequency 2
No.
(Hex.)
Name
Description
Default
(Range)
d7-02
(02B3)
RUN
Offset Frequency 2
Uses
H1-xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)]
as a percentage of the
Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.
0.0%
(-100.0 - +100.0%)
■
d7-03: Offset Frequency 3
No.
(Hex.)
Name
Description
Default
(Range)
d7-03
(02B4)
RUN
Offset Frequency 3
Uses
H1-xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)]
as a percentage of the
Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.
0.0%
(-100.0 - +100.0%)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV