1.22 Parameters Changed by PM Motor Code Selection
158
YASKAWA
TOEPYAIGA8002B GA800 Drive Programming
No.
Name
Unit
Motor Code (setting value of E5-01)
L3-24
Motor Accel Time @ Rated
Torque
s
0.085
0.080
0.122
0.108
0.161
0.160
0.175
n5-02
Motor Inertia Acceleration
Time
s
0.085
0.080
0.122
0.108
0.161
0.160
0.175
n8-49
Heavy Load Id Current
%
-15.1
-16.0
-15.7
-11.5
-6.8
-11.5
-14.8
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 1.15 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
1346
1347
1348
1349
Voltage Class
V
400
400
400
400
Capacity
kW
75
90
110
132
Motor Rotation Speed
min
-1
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
75.00
90.00
110.00
132.00
E5-03
PM Motor Rated Current (FLA)
A
124.0
153.1
186.5
226.0
E5-04
PM Motor Pole Count
-
6
6
6
6
E5-05
PM Motor Resistance (ohms/phase)
Ω
0.028
0.024
0.015
0.011
E5-06
PM d-axis Inductance (mH/phase)
mH
2.32
2.20
1.45
1.23
E5-07
PM q-axis Inductance (mH/phase)
mH
2.97
3.23
1.88
1.67
E5-09
PM Back-EMF Vpeak (mV/(rad/s))
mVs/rad
639.3
708.0
640.7
677.0
E5-24
PM Back-EMF L-L Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
72.5
72.5
72.5
72.5
E1-05
Maximum Output Voltage
V
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
E1-09
Minimum Output Frequency
Hz
3.6
3.6
3.6
3.6
C5-17
Motor Inertia
kgm
2
0.56
0.83
0.96
1.61
L3-24
Motor Accel Time @ Rated Torque
s
0.171
0.213
0.201
0.281
n5-02
Motor Inertia Acceleration Time
s
0.171
0.213
0.201
0.281
n8-49
Heavy Load Id Current
%
-15.8
-19.6
-14.9
-15.1
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 1.16 SSR1 Series Motor Code Setting for Specification of 200 V at 1150 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
-
1402
1403
1405
1406
1408
140A
140B
140D
Voltage Class
V
200
200
200
200
200
200
200
200
Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Motor Rotation Speed
min
-1
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
E5-03
PM Motor Rated Current
(FLA)
A
1.88
3.02
6.00
8.85
14.27
20.21
26.67
39.9
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
6
6
E5-05
PM Motor Resistance
(ohms/phase)
Ω
4.832
2.704
1.114
0.511
0.412
0.303
0.165
0.113
E5-06
PM d-axis Inductance
(mH/phase)
mH
48.68
32.31
19.22
12.15
7.94
11.13
6.59
4.96
E5-07
PM q-axis Inductance
(mH/phase)
mH
63.21
40.24
24.38
15.35
11.86
14.06
8.55
6.12