11 Appendix
11.2.1 List of Parameters
11-4
Pn002
2
Application Function
Select Switch 2
0000 to
4113
−
0011
After restart
Setup
−
−
Pn008
2
Application Function
Select Switch 8
0000 to
7121
−
4000
After restart
Setup
−
−
∗1.
Refer to the
Σ
-V-MD Series User’s Manual MECHATROLINK-III Standard Servo Profile Commands
(Manual No.:
SIEP S800001 03) for details.
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
4th 3rd 2nd 1st
digit digit digit digit
n.
Position/Speed Control Torque Limit Option
Reference
Section
0
Do not use torque limit TLIM in position or speed control commands.
*1
1
Use torque limit TLIM in position or speed control commands.
Torque Control Speed Limit Option
Reference
Section
0
Do not use speed limit VLIM in torque control commands.
*1
1
V_LIM operates as the speed limit value.
Absolute Encoder Usage
Reference
Section
0
Uses absolute encoder as an absolute encoder.
7.6
1
Uses absolute encoder as an incremental encoder.
Reserved (Do not change.)
Lowered Battery Voltage Alarm/Warning Selection
Reference
Section
0
Outputs alarm (A.830) for lowered battery voltage.
5.5.4
1
Outputs warning (A.930) for lowered battery voltage.
Reserved (Do not change.)
Warning Detection Selection
Reference
Section
0
Detects warning.
10.3.1
1
Does not detect warning.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.