11.2 List of Parameters
11-5
11
Appendix
Pn009
2
Application Function
Select Switch 9
0000 to
0111
−
0010
After restart
Tuning
−
−
Pn00B
2
Application Function
Select Switch B
0000 to
1111
−
0000
After restart
Setup
−
−
Pn00D
2
Application Function
Select Switch D
0000 to
1001
−
0000
Immediately
Setup
−
6.3.2
Pn010
2
Slot 1 Axis Address
0 to 15
−
0
After restart
Setup
−
7.1.2
Pn011
2
Slot 2 Axis Address
0 to 15
−
1
After restart
Setup
−
7.1.2
Pn012
2
Slot 3 Axis Address
0 to 15
−
2
After restart
Setup
−
7.1.2
Pn013
2
Slot 4 Axis Address
0 to 15
−
3
After restart
Setup
−
7.1.2
Pn014
2
Slot 5 Axis Address
0 to 15
−
4
After restart
Setup
−
7.1.2
Pn015
2
Slot 6 Axis Address
0 to 15
−
5
After restart
Setup
−
7.1.2
Pn016
2
Slot 7 Axis Address
0 to 15
−
6
After restart
Setup
−
7.1.2
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
Reserved (Do not change.)
Reserved (Do not change.)
Speed Detection Method Selection
Reference
Section
0
Speed detection 1
8.8.4
1
Speed detection 2
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
Alarm Gr.2 Stop Method Selection
Reference
Section
0
Stops the motor by setting the speed reference to "0".
7.3.5
1
Stops the motor by coasting.
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
Reference
Section
0
Does not detect overtravel warning.
7.3.2
1
Detects overtravel warning.
4th 3rd 2nd 1st
digit digit digit digit
n.