![YASKAWA E-V-MD Series User Manual Download Page 295](http://html1.mh-extra.com/html/yaskawa/e-v-md-series/e-v-md-series_user-manual_3588034295.webp)
11 Appendix
11.2.1 List of Parameters
11-12
Pn460
2
Notch Filter Adjustment
Switch
0000 to
0101
−
0101
Immediately
Tuning
−
8.2.1,
8.3.1,
8.5.1
Pn506
2
Brake Reference
-
Servo OFF Delay Time
0 to 50
10 ms
0
Immediately
Setup
−
7.3.4
Pn507
2
Brake Reference Output
Speed Level
0 to 10000 1 min
-1
100
Immediately
Setup
−
7.3.4
Pn508
2
Waiting Time for Brake
Signal When Motor
Running
10 to 100
10 ms
50
Immediately
Setup
−
7.3.4
Pn509
2
Reserved (Do not change.)
−
−
20
−
−
−
−
Pn51E
2
Excessive Position Error
Warning Level
10 to 100
1%
100
Immediately
Setup
–
10.3.1
Pn520
4
Excessive Position Error
Alarm Level
1 to
1073741823
1
refer-
ence
unit
5242880 Immediately
Setup
–
8.1.4,
10.2.1
Pn52B
2
Overload Warning Level
1 to 100
1%
20
Immediately
Setup
–
7.3.6
Pn52C
2
Derating of Base Current
at Detecting Overload of
Motor
10 to 100
1%
100
After restart
Setup
–
7.3.6
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
Notch Filter Adjustment Selection 1
0
Does not adjust 1st step notch filter automatically using utility function.
1
Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0
Does not adjust 2nd step notch filter automatically using utility function.
1
Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.