![YASKAWA E-V-MD Series User Manual Download Page 162](http://html1.mh-extra.com/html/yaskawa/e-v-md-series/e-v-md-series_user-manual_3588034162.webp)
8.3 Advanced Autotuning
8-29
8
Adjustments
14.
After confirming that the value displayed in the identified moment of inertia (mass) ratio and the
value displayed in the Pn103: Moment of Inertia Ratio are the same, click
Finish
.
The following window will appear.
15.
Click
OK
.
The following window will appear
16.
Click
Execute
to save the change of Pn103 (Moment of Inertia (Mass) Ratio) to SERVOPACK.
After the saving is finished, the tuning main window will appear.
This completes the moment of inertia (mass) identification procedure.