9 Utility Functions
9-22
9.9
Write Prohibited Setting
This function prevents changing parameters by mistake and sets restrictions on the execution of the utility
function.
Parameter changes and execution of the utility function become restricted in the following manner when Write
prohibited (P.0001) is assigned to the write prohibited setting parameter (Fn010).
• Parameters: Parameters can be changed from the S.
• Utility Function: Some functions cannot be executed. (Refer to the following table.) If you attempt to exe-
cute these utility functions a warning dialog box will appear.
Function
Write Prohibited
Setting
Reference
Section
Alarm history display
Executable
9.2
JOG operation
Cannot be executed
9.3
Origin search
Cannot be executed
9.4
Program JOG operation
Cannot be executed
9.5
Initializing parameter settings
Cannot be executed
9.6
Clearing alarm history
Cannot be executed
9.7
Absolute encoder multiturn reset and encoder alarm reset
Cannot be executed
7.6.1
Automatic offset-signal adjustment of the motor current detection
signal
Cannot be executed
9.8
Write prohibited setting
–
9.9
Multiturn limit value setting change when a multiturn limit dis-
agreement alarm occurs
Cannot be executed
7.6.2
Vibration detection level initialization
Cannot be executed
9.10
Confirmation of SERVOPACK and servomotor model informa-
tion
Executable
9.11
Software reset
Executable
9.12
EasyFFT
Cannot be executed
9.13
Online vibration monitor
Cannot be executed
9.14