![YASKAWA E-V-MD Series User Manual Download Page 137](http://html1.mh-extra.com/html/yaskawa/e-v-md-series/e-v-md-series_user-manual_3588034137.webp)
8 Adjustments
8.1.2 Basic Adjustment Procedure
8-4
8.1.2
Basic Adjustment Procedure
The basic adjustment procedure is shown in the following flowchart. Make suitable adjustments considering
the conditions and operating requirements of the machine
Completed.
Start adjusting servo gain.
(2) Adjust using Advanced Autotuning.
Execute moment of inertia (mass) identification and autotuning without
a host reference from the S.
Refer to
8.3 Advanced Autotuning
.
(3) Adjust using Advanced Autotuning by Reference.
Execute autotuning with a host reference from the S.
Refer to
8.4 Advanced Autotuning by Reference
.
Results OK?
Yes
Results OK?
Yes
Completed.
No
No
Results OK?
No
Completed.
Yes
Completed.
(1) Adjust using Tuning-less Function.
Runs the servomotor without any adjustments.
Refer to
8.2 Tuning-less Function
.
Results OK?
Yes
No
(4)Adjust using One-parameter Tuning.
Execute custom tuning from the S.
Refer to
8.5 One-parameter Tuning
.
Continuous vibration occurs.
Reduce the vibration using Anti-resonance Control Adjustment Function.
Refer to
8.6 Anti-Resonance Control Adjustment Function
.
Residual vibration occurs at positioning.
Reduce the vibration using Vibration Suppression Function.
Refer to
8.7 Vibration Suppression Function
.
Results OK?
Yes
No