11.2 List of Parameters
11-13
11
Appendix
Pn530
2
Program JOG Operation
Related Switch
0000 to
0005
−
0000
Immediately
Setup
−
9.5
Pn531
4
Program JOG Movement
Distance
1 to
1073741824
1
refer-
ence
unit
32768
Immediately
Setup
−
9.5
Pn533
2
Program JOG Movement
Speed
1 to 10000 1 min
-1
500
Immediately
Setup
−
9.5
Pn534
2
Program JOG Accelera-
tion/Deceleration Time
2 to 10000
1 ms
100
Immediately
Setup
−
9.5
Pn535
2
Program JOG Waiting
Time
0 to 10000
1 ms
100
Immediately
Setup
−
9.5
Pn536
2
Number of Times of
Program JOG Movement
0 to 1000
1 time
1
Immediately
Setup
−
9.5
Pn560
2
Remained Vibration
Detection Width
1 to 3000
0.1%
400
Immediately
Setup
−
8.7.1
Pn561
2
Overshoot Detection
Level
0 to 100
1%
100
Immediately
Setup
−
8.3.1,
8.4.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Profile Reference
Section
Program JOG Operation Switch
0
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
1
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
2
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
3
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
4
(Waiting time Pn535
→
Forward movement Pn531
→
Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
5
(Waiting time Pn535
→
Reverse movement Pn531
→
Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.