56
MAINTENANCE SPECIFICATIONS
SPEC
Model
RX10K, RX10RK, RX10RSK, RXW10K,
RXW10SK, RX10MK, RX10MSK
Carburetor:
Type / Quantity
Manufacturer
I.D. mark
Main jet
(M.J)
Main air jet
(M.A.J)
Jet needle
(J.N)
Needle jet
(N.J)
Pilot jet
(P.J)
Pilot air jet
(P.A.J.)
Pilot outlet
(P.O)
Bypass 1
(B.P.1)
(B.P.2)
(B.P.3)
Pilot screw
(P.S)
Throttle valve
(Th.V)
Valve seat size
(V.S)
Starter jet
(G.S)
Float height
(F.H)
Fuel level (below the line on the float
chamber)
Engine idle speed
BSR37/ 4
MIKUNI
8FA102
#135
#120
5DHP50-53-3
P4M
#17.5
#140
1.0
0.8
0.8
0.8
Approx 2
#115
1.5
#75
11
X
15 mm (0.43
X
0.59 in)
3.0
X
4.0 mm (1.118
X
0.157 in)
1,350
±
100 r / min (1,250
X
1,450 r / min)
Fuel pump:
Type
Manufacturer
Diaphragm
8FA (MIKUNI)
Oil filter:
Oil filter type
Bypass valve opening pressure
Cartridge (paper)
78
X
118 kPa (0.78
X
1.18 kg / cm
2
,
11.1
X
16.8 psi)
Oil pump:
Oil pump type
Inner-rotor-to-outer-rotor-tip
clearance
Outer-rotor-to-oil-pump-housing
clearance
Max. impeller shaft tilt
<Limit>
Relief valve operating pressure
Oil pressure (hot)
Trochoidal
0.00
X
0.12 mm (0.000
X
0.005 in)
0.09
X
0.15 mm (0.004
X
0.006 in)
0.15 mm (0.0059 in)
0.072 mm (0.0028 in)
430
X
550 kPa (4.3
X
5.5 kg / cm
2
, 61.2
X
78.2 psi)
50 kPa (0.5 kg / cm
2
, 7.1 psi) at 1,450 r / min
Cooling system:
Filler cap opening pressure
Water pump type
Reduction ratio
Coolant type
Coolant mixing ratio (coolant: water)
Capacity
95
X
125 kPa (0.95
X
1.25 kg / cm
2
, 14
X
18 psi)
Single-suction centrifugal pump (Impeller type)
37 / 31
23 / 18 (1.525)
High quality silicate-free ethylene glycol antifreeze
containing corrosion inhibitors
3 : 2 (60% : 40%)
4.9 L (4.32 Imp qt, 5.18 US qt) (RX10K, RX10RK,
RX10RSK, RXW10K, RXW10SK)
6.4 L (5.64 Imp qt, 6.76 US qt) (RX10MK, RX10MSK)
Summary of Contents for RX10K
Page 1: ...SUPPLEMENTARY SERVICE MANUAL LIT 12618 02 39 ...
Page 76: ...72 CABLE ROUTING SPEC ...
Page 78: ...74 CABLE ROUTING SPEC ...
Page 80: ...76 CABLE ROUTING SPEC ...
Page 82: ...78 CABLE ROUTING SPEC ...
Page 84: ...80 CABLE ROUTING SPEC ...
Page 86: ...82 CABLE ROUTING SPEC ...
Page 88: ...84 CABLE ROUTING SPEC ...
Page 90: ...86 CABLE ROUTING SPEC ...
Page 92: ...88 CABLE ROUTING SPEC ...
Page 94: ...90 CABLE ROUTING SPEC ...
Page 96: ...92 CABLE ROUTING SPEC ...
Page 98: ...94 CABLE ROUTING SPEC ...
Page 100: ...96 CABLE ROUTING SPEC ...
Page 102: ...98 CABLE ROUTING SPEC ...
Page 104: ...100 CABLE ROUTING SPEC ...
Page 106: ...102 CABLE ROUTING SPEC ...
Page 110: ...05 11 0 8 E ITP PRINTED ON RECYCLED PAPER ...
Page 111: ...SERVICE MANUAL ...
Page 371: ...8 19 LIGHTING SYSTEM CIRCUIT DIAGRAM LIGHTING SYSTEM ELEC ...
Page 377: ...8 25 SIGNAL SYSTEM ELEC SIGNAL SYSTEM CIRCUIT DIAGRAM ...
Page 389: ...GRIP WARMER SYSTEM ELEC 8 37 HI LO GRIP WARMER SYSTEM CIRCUIT DIAGRAM ...
Page 394: ...8 42 CARBURETOR HEATER SYSTEM ELEC HI LO B W L R CARBURETOR HEATER SYSTEM CIRCUIT DIAGRAM ...
Page 423: ...9 23 CABLE ROUTING SPEC ...
Page 425: ...9 25 CABLE ROUTING SPEC ...
Page 427: ...9 27 CABLE ROUTING SPEC ...
Page 429: ...9 29 CABLE ROUTING SPEC ...
Page 431: ...9 31 CABLE ROUTING SPEC ...
Page 433: ...9 33 CABLE ROUTING SPEC ...
Page 435: ...9 35 CABLE ROUTING SPEC ...
Page 437: ...9 37 CABLE ROUTING SPEC ...
Page 440: ... 01 05 0 8 E ITP PRINTED ON RECYCLED PAPER ...
Page 441: ......
Page 505: ...60 CABLE ROUTING SPEC ...
Page 507: ...62 CABLE ROUTING SPEC ...
Page 509: ...64 CABLE ROUTING SPEC ...
Page 511: ...66 CABLE ROUTING SPEC ...
Page 513: ...68 CABLE ROUTING SPEC ...
Page 515: ...70 CABLE ROUTING SPEC ...
Page 517: ...72 CABLE ROUTING SPEC ...
Page 519: ...74 CABLE ROUTING SPEC ...
Page 522: ......