3-1 I/O Signals
3-1
I/O Signals
The standard I/O connector of the DRCX controller has 48 pins, with an individual signal assigned to
each pin. The following table shows the pin number as well as the name and description of each
signal assigned to each pin. For a more detailed description of each signal, refer to "3-2 Input Signal
Description" and onwards.
No.
Pin No.
Signal name
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
A1
B1
A2
B2
A3
B3
A4
B4
A5
B5
A6
B6
A7
B7
A8
B8
A9
B9
A10
B10
A11
B11
A12
B12
A13
B13
A14
B14
A15
B15
A16
B16
A17
B17
A18
B18
A19
B19
A20
B20
A21
B21
A22
B22
A23
B23
A24
B24
ABS-PT
INC-PT
AUTO-R
STEP-R
ORG-S
RESET
SERVO
LOCK
DI 0
DI 1
DI 2
DI 3
DI 4
DI 5
DI 6
DI 7
DI 8
DI 9
DI 10
DI 11
DI 12
DI 13
DI 14
DI 15/SVCE
+IN COM
+IN COM
+24V
+24V
0V
0V
DO 0
DO 1
DO 2
DO 3
DO 4
END
BUSY
READY
DO 5
DO 6
DO 7
DO 8
DO 9
DO 10
DO 11
DO 12
EMG 1
EMG 2
Absolute point movement command
Relative point movement command
Automatic operation start command
Step operation start command
Return-to-origin command
Reset command
Servo recovery command
Interlock
General-purpose input 0
General-purpose input 1
General-purpose input 2
General-purpose input 3
General-purpose input 4
General-purpose input 5
General-purpose input 6
General-purpose input 7
General-purpose input 8
General-purpose input 9
General-purpose input 10
General-purpose input 11
General-purpose input 12
General-purpose input 13
General-purpose input 14
General-purpose input 15/SERVICE mode input
Ex24V power supply input for controller
Ex24V power supply input for controller
In24V power supply output for controller
In24V power supply output for controller
Reference 0V for input/output
Reference 0V for input/output
General-purpose output 0
General-purpose output 1
General-purpose output 2
General-purpose output 3
General-purpose output 4
End-of-run output
Command-in-progress output
Ready-to-operate output
General-purpose output 5
General-purpose output 6
General-purpose output 7
General-purpose output 8
General-purpose output 9
General-purpose output 10
General-purpose output 11
General-purpose output 12
Emergency stop input 1 (used with EMG2)
Emergency stop input 2 (used with EMG1)
c
CAUTION
Terminals A14 and B14 are used as the output terminals of the internal 24V power supply. Do not connect these
terminals to the external 24V power supply. Otherwise the controller might malfunction.
n
NOTE
Terminal B12 functions as the SERVICE mode input terminal only when the SERVICE mode function is enabled.