3-
14
3
I/O INTERF
ACE
3-5 I/O Connection Diagram
3-5-3 Connection to PLC input unit using external 24V power supply
Connection to the Mitsubishi
©
PLC AX41 input unit
AX41 type input unit
DRCX series controller
External DC 24V
power supply
Photocoupler
Internal
circuit
X01
X00
X02
X03
X04
X05
X06
X07
DC24V
X08
X09
X0A
X0B
X0C
X0D
X0E
X0F
DC24V
B19
A19
B18
A16
B16
A17
B17
A18
A20
B20
A21
B21
A22
B22
A23
B23
TB 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
A13,B13
A15,B15
READY
BUSY
END
DO 0
DO 1
DO 2
DO 3
DO 4
DO 5
DO 6
DO 7
DO 8
DO 9
DO 10
DO 11
DO 12
+IN COM
0V
+
-
R
R