11-
36
11
COMMUNICA
TION WITH PC
11-5 Communication Command Description
(5)@SDEL <program number>,<step number>
Deletes a specified step.
Program number
: This is a number used to identify each program and can be from 0
to 99.
Step number
: This is a number used to identify each step and can be from 1 to
255.
Transmission example
: @SDEL 31,99 c/r l/f .................... Deletes step 99 of program
No. 31.
Response example 1
: OK c/r l/f
Response example 2
: NG c/r l/f ...................................... The specified step number is
not registered.
42: cannot find step
c/r l/f
(6)@SMOD <program number>,<step number>
Modifies data in a specified step. The DRCX controller will transmit READY when this com-
mand is received. Confirm that READY is received and then transmit the modification data.
Program number
: This is a number used to identify each program and can be from 0
to 99.
Step number
: This is a number used to identify each step and can be from 1 to
255.
Transmission example 1
:
Send
Receive
@SMOD 0,5 c/r l/f
READY c/r l/f
TIMR 50 c/r l/f
OK c/r l/f
Transmission example 2
:
Send
Receive
@SMOD 0,5 c/r l/f
NG c/r l/f
43: cannot find PGM c/r l/f
(7)@COPY <program number (copy source)>,<program number (copy destination)>
Copies a program. If a program exists in the copy destination, the program will be rewritten.
Program number
: This is a number used to identify each program and can be from 0
to 99.
Transmission example
: @COPY 0,1 c/r l/f ........................ Copies program No. 0 to
program No. 1.
Response example 1
: OK c/r l/f
Response example 2
: NG c/r l/f ...................................... The program to be copied is
not registered.
43: cannot find PGM c/r l/f