10-
2
10
OTHER OPERA
TIONS
10-1 Initialization
10-1 Initialization
Initializing the programs and points erases all the program data and point data currently stored in the
controller.
Initializing the parameters resets the parameters to their initial values.
1) On the initial screen, press
F3
(SYS).
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1PRM 2B.UP3INIT
[SYS-INIT]
select menu
1PGM 2PNT 3PRM 4ALL
[SYS-INIT-PRM]
select menu
1XY 2FLIP
[SYS-INIT-PRM-XY]
robot type : 110_
refer to
robot type table
2) Next, press
F3
(INIT).
3) Select the data to be initialized.
To initialize the program data, press
F1
(PGM).
To initialize the point data, press
F2
(PNT).
To initialize the parameter data, press
F3
(PRM).
To initialize all of the program, point and pa-
rameter data, press
F4
(ALL).
4) If
F3
(PRM) or
F4
(ALL) was selected in
step 3, the robot type must be selected.
When using a dual-axis robot, press
F1
(XY).
When using two single-axis robots (Multi-Flip),
press
F2
(FLIP).
5) If
F1
(XY) was selected, enter the dual-axis
robot type number with the number keys and
then press the
key.
For the robot number, see "15-1-2 Robot
number list".
The screen at the right is an example showing
that the SXYx robot is selected.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com