7.
If you want to remove one of the regions from the camera picture, click the red box in the
region and then click
Remove
button. Click
Remove All
will delete all regions.
Notice:
1)
The perimeter must not be too close to the edges/corners of the camera picture, since it may
fail to trigger the detection when the target pass through the edges/corners.
2)
The shape of the regions shall not be too narrow/small, since it may fail to trigger the detection
when the target passes through outside the perimeter.
5.1.8.2 LCD (Line Crossing Detection)
Line Crossing Detection function detects people, vehicle or other objects which cross
a pre-defined virtual line, and some certain actions can be taken when the alarm is
triggered.
Channel
: Select the channel you want to configure
Switch
: Enable or disable the LCD function