Trigger, turn the trigger output on/off (repeatable). As it has multiple functions, the values in
this field have several meanings:
If the 2
nd
digit is zero and the first has a value:
10 triggers very shortly ON/OFF (5ms)
20 triggers ON/OFF with a longer ON (10ms)
30 triggers ON/OFF with an even longer ON time (15ms)
….. up to D0
If the 1
st
digit is zero and the 2
nd
digit has a value it has a (inverted) function which results in
a delayed gate:
01 triggers OFF/ON shortly (delayed gate, 5ms delay)
02 triggers OFF/ON with a longer OFF time (delayed gate, 10ms delay)
03 triggers OFF/ON with an even longer OFF time (delayed gate, 15ms delay)
….. up to 0F
Keep in mind that you might want to reset the trigger again in the new row or before by
using the kill command.
If both the 1
st
and the 2
nd
digit have a value then the trigger will repeat.
The first digit is for the trigger length where again 1 is the shortest trigger and F the longest.
Trigger/Pause times are equal here. The 2
nd
digit is for the amount of repetitions, where 1 is
one repetition (2 trigger pulses) and F are 15 repetitions (16 trigger pulses).
22 triggers ON/OFF/ON/OFF/ON/OFF fast (10ms pulses)
23 triggers ON/OFF/ON/OFF/ON/OFF/ON/OFF fast (10 ms pulses)
52 triggers ON/OFF/ON/OFF slower (25ms pulses)
Furthermore there are special function numbers with which you can manipulate the trigger
outputs to generate ratcheting, BPM related trigger/gate lengths or to be set or reset.
00 Turns output OFF ( = reset Gate)
D0 Trigger 1 Tick long
D1 until DF Trigger 2 to 16 ticks long
E0 One step long Gate
E1 Ratcheting 1x (Half a step Gate)
E2 Ratcheting 2x (Duplets)
E3 Ratcheting 3x (Triplets)
E4 Ratcheting 4x (Quadruplet)
NerdSEQ – a tracker based Eurorack sequencer
Page 24
User Manual Revision V1.26 for Firmware V1.26
12 July 2022