![Xerox Nuvera 100 Software Manual Download Page 164](http://html2.mh-extra.com/html/xerox/nuvera-100/nuvera-100_software-manual_3360849164.webp)
Specifying input parameters
2-56
Using LCDS Print Description Language
VOLUME BMULT
Specifies a multiplication factor that you can use to determine
the true block length.
Syntax
VOLUME BMULT = value
Options
Default
1
VOLUME CODE
Specifies which code translation table the system uses to
interpret the input data.
Syntax
VOLUME CODE = {keyword | id | NONE}
Options
Table 2-57. VOLUME BMULT parameter options and definitions
Option
Definition
value
An integer from 1 to 15 that you extract from the tape label and apply as a
multiplication factor to the block length to determine the true block length
Table 2-58. VOLUME CODE parameter options and definitions
Option
Definition
keyword
Specifies a specific, standard, system defined code translation table. The
available options are:
•
ASCII
•
BCD
•
EBCDIC
•
H2BCD
•
H6BCD
•
IBMBCD
•
NONE
•
PEBCDIC
•
USER (Refers to the single unlabeled CODE command defined within the
JDL.)
id
Specifies an identifier label that you used in a previously defined CODE
command. The id label is required when multiple CODE commands are
contained within the JDL.
NONE
Specifies that data will not be translated by input processing.
Summary of Contents for Nuvera 100
Page 1: ...Xerox DocuPrint EPS Using LCDS Print Description Language 701P21091 Version 3 7 May 2003...
Page 16: ...Table of contents xvi Using LCDS Print Description Language...
Page 28: ...Introduction xxviii Using LCDS Print Description Language...
Page 352: ...Specifying print format parameters 4 112 Using LCDS Print Description Language...
Page 434: ...Using PDL commands for graphics 6 8 Using LCDS Print Description Language...
Page 464: ...Character code assignments C 8 Using LCDS Print Description Language...
Page 498: ...INDEX INDEX 12 Using LCDS Print Description Language...