1/05
2-10
DocuColor 12/DCCS50
+24 VDC Power (IIT/IPS LVPS) RAP, AC Power RAP
Reissue
Status Indicator RAPs
+24 VDC Power (IIT/IPS LVPS) RAP
This RAP is used to repair failures in the +24 VDC Power (IIT/IPS LVPS) circuit when directed
by another RAP.
Initial Actions
•
Use BSD 1.3 in the following procedure:
Procedure
Disconnect P/
J5
. Go to
Flag 1
on BSD 1.3, and check for ACH between P/
J5
-3 and P/
J5
-2
on the harness side.
ACH is measures between P/
J5
-3 and P/
J5
-2.
Y
N
Go to the
AC Power RAP
.
Go to
Flag 2
on BSD 1.3.
Less than +1 VDC is measured at
P/J11A
-1.
Y
N
Go to
Flag 3
on BSD 1.3.
Less than +1 VDC is measured at
P/J11A
-13.
Y
N
Perform the following:
•
Replace the IOT Drive PWB (
PL 9.2
).
•
Replace the IOT CPU PWB (
PL 9.2
).
Replace the AC Driver PWB (
PL 9.3
).
Go to
Flag 7
on BSD 1.3, and perform the following:
1.
Check the wiring from
P/J35
for an open/short circuit between the DADF Control PWB or
Lamp Ballast PWB.
2.
Replace the IIT/IPS LVPS (
PL 3.5
).
AC Power RAP
This RAP is used to repair failures in the AC Power circuit when directed by another RAP.
Initial Actions
•
Check that the specified level of AC Line voltage is present at the wall receptacle.
Procedure
With the machine plugged into the AC source and the Circuit Breaker and Main Switch
switched on, check that AC Line voltage is measured between
P/J17
-1,2,3 (ACH) and
P/J17
-
4,5,6 (ACN).
AC Line voltage checked OK between
P/J17
-1,2,3 and
P/J17
-4,5,6.
Y
N
Check for AC Line voltage between
P/J16
-1 (ACH) and
P/J16
-4 (ACN) on the AC Driver
PWB (
PL 9.3
).
AC Line voltage checked OK between
P/J16
-1 and
P/J16
-4.
Y
N
Check for AC Line voltage between
P/J15
-1and
P/J15
-3 on the AC Driver PWB (
PL
9.3
).
AC Line voltage is present between
P/J15
-1 and
P/J15
-3.
Y
N
Go to
Flag 1
on BSD 1.1, and check for an open circuit between
P/J16
on the
AC Driver PWB and the AC Plug on the Line Cord.
Replace the AC Driver PWB (
PL 9.3
).
With the machine plugged into the AC source, and the Circuit Breaker switched on, check
for 18 VAC between
P/J19
-6 and
P/J19
-12 on the AC Driver PWB (
PL 9.3
).
18 VAC is
present between
P/J19
-6 and
P/J19
-12.
Y
N
Go to
Flag 2
on BSD 1.1, and check for an open circuit.
Perform the following:
•
Go to
Flag 1
,
Flag 2
,
Flag 3
,
Flag 4
, and
Flag 5
on BSD 1.1 and check for open cir-
cuits. Also check for short circuits to ground at
Flag 3
,
Flag 4
, and
Flag 5
.
•
Replace the Main Switch (
PL 9.1
).
•
Replace the AC Driver PWB (
PL 9.3
).
•
Replace the IOT Drive PWB (
PL 9.2
).
+5 VDC is measured between
P/J11B
-17 and
P/J11B
-19.
Y
N
Go to
Flag 3
on BSD 1.1, and check for an open circuit. If the circuit is OK, replace the AC
Driver PWB (
PL 9.3
).
+24 VDC is measured between
P/J11A
B-15 and DC COM when the Main Switch is
switched ON.
Y
N
Go to
Flag 5
on BSD 1.1, and check for an open/short circuit. If the circuit is OK, perform
the following:
•
Go to the +24 VDC Wirenet and check for an open/short circuit.
•
Replace the AC Driver PWB (
PL 9.3
).
•
Replace the IOT Drive PWB (
PL 9.2
).
A
manuals4you.com
manuals4you.com
Summary of Contents for DocuColor 12/DCCS50
Page 4: ...1 05 ii DocuColor 12 DCCS50 Reissue Introduction manuals4you com manuals4you com...
Page 9: ...1 05 vii DocuColor 12 DCCS50 Introduction Reissue Figure 2 General Information...
Page 30: ...1 05 1 2 DocuColor 12 DCCS50 Reissue Service Call Procedures manuals4you com manuals4you com...
Page 276: ...1 05 3 2 DocuColor 12 DCCS50 Reissue Image Quality manuals4you com manuals4you com...
Page 850: ...1 05 6 170 DocuColor 12 DCCS50 Reissue General Procedures manuals4you com manuals4you com...
Page 852: ...1 05 7 2 DocuColor 12 DCCS50 Reissue Wiring Data manuals4you com manuals4you com...
Page 893: ...1 05 7 43 DocuColor 12 DCCS50 18VAC Wirenet Wiring Data Reissue Figure 1 Wirenet AC 18V...
Page 899: ...1 05 7 49 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 2 Wirenet 5VDC 2...
Page 901: ...1 05 7 51 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 4 Wirenet 5VDC 3...
Page 903: ...1 05 7 53 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 6 Wirenet 5VDC 4...
Page 905: ...1 05 7 55 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 8 Wirenet 5VDC 6...
Page 921: ...1 05 7 71 DocuColor 12 DCCS50 24VDC Wirenets Wiring Data Reissue Figure 3 Wirenet 24VDC 3...
Page 923: ...1 05 7 73 DocuColor 12 DCCS50 24VDC Wirenets Wiring Data Reissue Figure 5 Wirenet 24VDC 5...
Page 932: ...1 05 7 82 DocuColor 12 DCCS50 BSDs Reissue Wiring Data manuals4you com manuals4you com...
Page 943: ...1 05 7 93 DocuColor 12 DCCS50 Chain 02 Wiring Data Reissue Figure 3 BSD 2 2 UI Display...
Page 945: ...1 05 7 95 DocuColor 12 DCCS50 Chain 02 Wiring Data Reissue Figure 5 BSD 2 4 Monitoring...
Page 946: ...1 05 7 96 DocuColor 12 DCCS50 Chain 02 Reissue Wiring Data manuals4you com manuals4you com...
Page 953: ...1 05 7 103 DocuColor 12 DCCS50 Chain 03 Wiring Data Reissue Figure 7 BSD 3 6 Foreign Interface...
Page 956: ...1 05 7 106 DocuColor 12 DCCS50 Chain 03 Reissue Wiring Data manuals4you com manuals4you com...
Page 965: ...1 05 7 115 DocuColor 12 DCCS50 Chain 05 Wiring Data Reissue Figure 7 BSD 5 6 Monitoring...
Page 966: ...1 05 7 116 DocuColor 12 DCCS50 Chain 05 Reissue Wiring Data manuals4you com manuals4you com...
Page 969: ...1 05 7 119 DocuColor 12 DCCS50 Chain 06 Wiring Data Reissue Figure 3 BSD 6 3 Carriage Control...
Page 971: ...1 05 7 121 DocuColor 12 DCCS50 Chain 06 Wiring Data Reissue Figure 5 BSD 6 5 Laser Control...
Page 973: ...1 05 7 123 DocuColor 12 DCCS50 Chain 06 Wiring Data Reissue Figure 7 BSD 6 7 Monitoring 1 of 2...
Page 993: ...1 05 7 143 DocuColor 12 DCCS50 Chain 08 Wiring Data Reissue Figure 3 BSD 8 3 Tray 3 Paper Feed...
Page 995: ...1 05 7 145 DocuColor 12 DCCS50 Chain 08 Wiring Data Reissue Figure 5 BSD 8 5 Tray 5 Paper Feed...
Page 1009: ...1 05 7 159 DocuColor 12 DCCS50 Chain 09 Wiring Data Reissue Figure 5 BSD 9 3 Development...
Page 1043: ...1 05 7 193 DocuColor 12 DCCS50 Chain 10 Wiring Data Reissue Figure 15 BSD 10 11 OCT Control...
Page 1048: ...1 05 7 198 DocuColor 12 DCCS50 Chain 10 Reissue Wiring Data manuals4you com manuals4you com...
Page 1053: ...1 05 7 203 DocuColor 12 DCCS50 Chain 11 Wiring Data Reissue Figure 5 BSD 11 3 Decurler Control...
Page 1062: ...1 05 7 212 DocuColor 12 DCCS50 Chain 16 Reissue Wiring Data manuals4you com manuals4you com...
Page 1064: ...1 05 8a 2 DocuColor 12 DCCS50 Reissue High Capacity Feeder manuals4you com manuals4you com...
Page 1068: ...1 05 8a 6 DocuColor 12 DCCS50 Reissue High Capacity Feeder manuals4you com manuals4you com...
Page 1074: ...1 05 8a 12 DocuColor 12 DCCS50 Reissue High Capacity Feeder manuals4you com manuals4you com...
Page 1116: ...1 05 8b 2 DocuColor 12 DCCS50 Reissue Convenience Stapler manuals4you com manuals4you com...
Page 1126: ...1 05 8c 2 DocuColor 12 DCCS50 Reissue Edit Pad manuals4you com manuals4you com...
Page 1140: ...1 05 8c 16 DocuColor 12 DCCS50 Edit Pad BSDs Reissue Edit Pad manuals4you com manuals4you com...
Page 1144: ...1 05 8d 4 DocuColor 12 DCCS50 Reissue Finisher Sorter manuals4you com manuals4you com...
Page 1200: ...1 05 8d 58 DocuColor 12 DCCS50 12 580 Reissue Finisher Sorter manuals4you com manuals4you com...
Page 1376: ...1 05 9 2 DocuColor 12 DCCS50 Reissue Installation Instructions manuals4you com manuals4you com...
Page 1521: ...1 05 10 101 DocuColor 12 DCCS50 Overview Principles of Operation Reissue Figure 2 Paper Path...
Page 1605: ...1 05 10 185 DocuColor 12 DCCS50 Stacker Tray Motor and Sensors Principles of Operation Reissue...
Page 1614: ...1 05 11 2 DocuColor 12 DCCS50 Reissue Glossary of Terms manuals4you com manuals4you com...