1/05
3-37
DocuColor 12/DCCS50
IQ 38 Charge Corotron HVPS RAP, IQ 39 Preclean
Image Quality
Reissue
Press
Stop
. Perform the following:
•
Set the meter to measure micro amps.
•
Disconnect the Charge output connector from the CC/PCC HVPS.
•
Connect one meter lead to the supply side of the connector and the other lead to the har-
ness side.
•
Enter
dC330 [09-070]
. Press
Start
.
Approximately 600 to 800 micro amps is measured.
Y
N
Replace the CC/PCC HVPS (
PL 9.1
).
The Charge Corotron HVPS checks out OK. Check the following:
•
Charge Corotron Assy (
PL 5.4
).
•
Charge Corotron connector (
PL 5.2
).
IQ 39 Preclean Corotron HVPS RAP
This RAP is used to isolate the cause of missing or out-of-range voltages and current.
Procedure
WARNING
Electrical Shock Hazard. In the following procedure, high DC voltage circuits will be
tested. Use extreme caution when testing these circuits. Do not touch the multimeter or
the meter leads while testing the circuits.
Ensure that NVM location [774-031] is set at 3 and location [774-029] is set at 130. Enter and
operate DC330 [09-068]. Observe the G Monitor (Red) LED on the CC/PCC HVPS.
The LED
is lit.
Y
N
Enter and operate DC330 [09-070] and observe the B Monitor (Red) LED on the CC/PCC
HVPS.
The LED is lit.
Y
N
+24 VDC is measured at
P/J92
-1 on the CC/PCC HVPS.
Y
N
Go to
Flag 2
BSD9.13 and check for an open circuit. If OK, replace the IOT
Drive PWB (
PL 9.2
).
Check for an open connection between
P/J92
-1 and
P/J92
-1. If OK, replace the
CC/PCC HVPS (
PL 9.1
).
Approximately +1.85 VDC is measured at
P/J92
-6.
Y
N
Go to
Flag 3
BSD9.13 and check for an open circuit. If OK, replace the IOT Drive
PWB (
PL 9.2
).
Check for an open connection at
P/J92
-6. If OK, go to
Flag 4
BSD9.13 and check the
Preclean output circuit, including the Preclean Corotron wire (
PL 5.4
) for and open circuit.
If OK, replace the CC/PCC HVPS (
PL 9.1
).
Set your meter to measure micro amps. Disconnect the Preclean output connector from the
CC/PCC HVPS (
PL 9.1
). Connect one meter lead to the supply side of the connector and the
other lead to the harness side. Make another full-color copy.
Approximately 200 to 400
micro amps is measured.
Y
N
Replace the CC/PCC HVPS (
PL 9.1
).
The Preclean Corotron HVPS checks out OK. Check the following:
•
Preclean Corotron (
PL 5.4
).
•
Preclean Corotron connector (
PL 5.2
).
A
Summary of Contents for DocuColor 12/DCCS50
Page 4: ...1 05 ii DocuColor 12 DCCS50 Reissue Introduction manuals4you com manuals4you com...
Page 9: ...1 05 vii DocuColor 12 DCCS50 Introduction Reissue Figure 2 General Information...
Page 30: ...1 05 1 2 DocuColor 12 DCCS50 Reissue Service Call Procedures manuals4you com manuals4you com...
Page 276: ...1 05 3 2 DocuColor 12 DCCS50 Reissue Image Quality manuals4you com manuals4you com...
Page 850: ...1 05 6 170 DocuColor 12 DCCS50 Reissue General Procedures manuals4you com manuals4you com...
Page 852: ...1 05 7 2 DocuColor 12 DCCS50 Reissue Wiring Data manuals4you com manuals4you com...
Page 893: ...1 05 7 43 DocuColor 12 DCCS50 18VAC Wirenet Wiring Data Reissue Figure 1 Wirenet AC 18V...
Page 899: ...1 05 7 49 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 2 Wirenet 5VDC 2...
Page 901: ...1 05 7 51 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 4 Wirenet 5VDC 3...
Page 903: ...1 05 7 53 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 6 Wirenet 5VDC 4...
Page 905: ...1 05 7 55 DocuColor 12 DCCS50 5VDC Wirenets Wiring Data Reissue Figure 8 Wirenet 5VDC 6...
Page 921: ...1 05 7 71 DocuColor 12 DCCS50 24VDC Wirenets Wiring Data Reissue Figure 3 Wirenet 24VDC 3...
Page 923: ...1 05 7 73 DocuColor 12 DCCS50 24VDC Wirenets Wiring Data Reissue Figure 5 Wirenet 24VDC 5...
Page 932: ...1 05 7 82 DocuColor 12 DCCS50 BSDs Reissue Wiring Data manuals4you com manuals4you com...
Page 943: ...1 05 7 93 DocuColor 12 DCCS50 Chain 02 Wiring Data Reissue Figure 3 BSD 2 2 UI Display...
Page 945: ...1 05 7 95 DocuColor 12 DCCS50 Chain 02 Wiring Data Reissue Figure 5 BSD 2 4 Monitoring...
Page 946: ...1 05 7 96 DocuColor 12 DCCS50 Chain 02 Reissue Wiring Data manuals4you com manuals4you com...
Page 953: ...1 05 7 103 DocuColor 12 DCCS50 Chain 03 Wiring Data Reissue Figure 7 BSD 3 6 Foreign Interface...
Page 956: ...1 05 7 106 DocuColor 12 DCCS50 Chain 03 Reissue Wiring Data manuals4you com manuals4you com...
Page 965: ...1 05 7 115 DocuColor 12 DCCS50 Chain 05 Wiring Data Reissue Figure 7 BSD 5 6 Monitoring...
Page 966: ...1 05 7 116 DocuColor 12 DCCS50 Chain 05 Reissue Wiring Data manuals4you com manuals4you com...
Page 969: ...1 05 7 119 DocuColor 12 DCCS50 Chain 06 Wiring Data Reissue Figure 3 BSD 6 3 Carriage Control...
Page 971: ...1 05 7 121 DocuColor 12 DCCS50 Chain 06 Wiring Data Reissue Figure 5 BSD 6 5 Laser Control...
Page 973: ...1 05 7 123 DocuColor 12 DCCS50 Chain 06 Wiring Data Reissue Figure 7 BSD 6 7 Monitoring 1 of 2...
Page 993: ...1 05 7 143 DocuColor 12 DCCS50 Chain 08 Wiring Data Reissue Figure 3 BSD 8 3 Tray 3 Paper Feed...
Page 995: ...1 05 7 145 DocuColor 12 DCCS50 Chain 08 Wiring Data Reissue Figure 5 BSD 8 5 Tray 5 Paper Feed...
Page 1009: ...1 05 7 159 DocuColor 12 DCCS50 Chain 09 Wiring Data Reissue Figure 5 BSD 9 3 Development...
Page 1043: ...1 05 7 193 DocuColor 12 DCCS50 Chain 10 Wiring Data Reissue Figure 15 BSD 10 11 OCT Control...
Page 1048: ...1 05 7 198 DocuColor 12 DCCS50 Chain 10 Reissue Wiring Data manuals4you com manuals4you com...
Page 1053: ...1 05 7 203 DocuColor 12 DCCS50 Chain 11 Wiring Data Reissue Figure 5 BSD 11 3 Decurler Control...
Page 1062: ...1 05 7 212 DocuColor 12 DCCS50 Chain 16 Reissue Wiring Data manuals4you com manuals4you com...
Page 1064: ...1 05 8a 2 DocuColor 12 DCCS50 Reissue High Capacity Feeder manuals4you com manuals4you com...
Page 1068: ...1 05 8a 6 DocuColor 12 DCCS50 Reissue High Capacity Feeder manuals4you com manuals4you com...
Page 1074: ...1 05 8a 12 DocuColor 12 DCCS50 Reissue High Capacity Feeder manuals4you com manuals4you com...
Page 1116: ...1 05 8b 2 DocuColor 12 DCCS50 Reissue Convenience Stapler manuals4you com manuals4you com...
Page 1126: ...1 05 8c 2 DocuColor 12 DCCS50 Reissue Edit Pad manuals4you com manuals4you com...
Page 1140: ...1 05 8c 16 DocuColor 12 DCCS50 Edit Pad BSDs Reissue Edit Pad manuals4you com manuals4you com...
Page 1144: ...1 05 8d 4 DocuColor 12 DCCS50 Reissue Finisher Sorter manuals4you com manuals4you com...
Page 1200: ...1 05 8d 58 DocuColor 12 DCCS50 12 580 Reissue Finisher Sorter manuals4you com manuals4you com...
Page 1376: ...1 05 9 2 DocuColor 12 DCCS50 Reissue Installation Instructions manuals4you com manuals4you com...
Page 1521: ...1 05 10 101 DocuColor 12 DCCS50 Overview Principles of Operation Reissue Figure 2 Paper Path...
Page 1605: ...1 05 10 185 DocuColor 12 DCCS50 Stacker Tray Motor and Sensors Principles of Operation Reissue...
Page 1614: ...1 05 11 2 DocuColor 12 DCCS50 Reissue Glossary of Terms manuals4you com manuals4you com...