Operation
Using the Shutdown Function
68
Operating Manual for XKW 3kW Series Power Supply
Figure 3.18
Using Shutdown with an AC or DC Input (Negative Logic)
Shutdown
Application
Contact
Closure
An external relay, whether normally open or normally closed, may be used to
activate the Shutdown circuit. Either positive or negative logic may be used.
To activate the Shutdown function using an external relay:
1. Turn off the power supply and disconnect the AC power source. Allow five (5)
minutes to elapse to dissipate stored energy before making connections or
resetting switches. Refer to
“Configuring for Remote Programming, Sensing,
and Monitoring” on page 48
for instructions for resetting switches or making J3
connections.
2. Connect one side of the external relay to pin 15 (+15Vdc Auxiliary Output) on
connector J3. Connect the other side of the relay to pin 14 (TTL Shutdown
Input). Also connect pin 2 (Shutdown Return) to pin 6 (Auxiliary Supply
Ground). See
Figure 3.19
through
Figure 3.22
.
3. Set internal switch SW1-8 to select the desired circuit logic as set out in
Table 3.4
.
+
-
AC/DC SOURCE ON = OUTPUT OFF
AC/DC SOURCE OFF = OUTPUT ON
12-250Vac
or 12-130Vdc
SOURCE
J3
8 7 6 5 4 3 2 1
TM-25OP-01XN.book Page 68 Monday, April 5, 2004 8:58 AM
Summary of Contents for XKW 12-150
Page 2: ......
Page 3: ...Operating Manual for XKW 3000 Watt Series Programmable DC Power Supply...
Page 14: ...xii Operating Manual for XKW 3kW Series Power Supply...
Page 18: ...List of Tables xvi Operating Manual for XKW 3kW Series Power Supply...
Page 28: ...Features and Specifications Specifications 26 Operating Manual for XKW 3kW Series Power Supply...
Page 48: ...Installation Using Remote Sensing 46 Operating Manual for XKW 3kW Series Power Supply...
Page 80: ...Operation Using Multiple Supplies 78 Operating Manual for XKW 3kW Series Power Supply...
Page 89: ......