Operation
Remote Programming of Output Voltage and Current Limit
Revision A
61
Programming Output Current Limit with a 0-1mA Source
1. Remove the jumper between pins 22 and 23 of connector J3.
2. Connect the external programming source between pin 10 (current limit
programming input/positive) and pin 12 (return) of connector J3.
Varying the current source from 0 to 1mA will vary the current limit from 0 to 100%
of the model rating. The output voltage is set by adjusting the front panel voltage
control.
Figure 3.11
Programming Output Current Limit with a 0-1mA Source
Programming Output Current Limit with a 0-5k Resistance
1. Remove the jumpers connecting pins 10 to 11 and pins 22 to 23 on connector J3.
2. Connect pins 10 (current limit programming input/positive) and 22 (1mA
current source for current control) to the counterclockwise end of the 5k
potentiometer and connect the tap and clockwise end of the potentiometer to pin
12 (return).
Adjusting the resistance from 0 to 5k will vary the current limit from 0 to 100% of
the model rating. The output voltage is set by adjusting the front panel voltage
control.
Figure 3.12
Programming Output Current Limit with a 5k ohm Resistance
+
0 - 1 mA
J3
0 - 5 k
Ω
J3
TM-25OP-01XN.book Page 61 Monday, April 5, 2004 8:58 AM
Summary of Contents for XKW 12-150
Page 2: ......
Page 3: ...Operating Manual for XKW 3000 Watt Series Programmable DC Power Supply...
Page 14: ...xii Operating Manual for XKW 3kW Series Power Supply...
Page 18: ...List of Tables xvi Operating Manual for XKW 3kW Series Power Supply...
Page 28: ...Features and Specifications Specifications 26 Operating Manual for XKW 3kW Series Power Supply...
Page 48: ...Installation Using Remote Sensing 46 Operating Manual for XKW 3kW Series Power Supply...
Page 80: ...Operation Using Multiple Supplies 78 Operating Manual for XKW 3kW Series Power Supply...
Page 89: ......