Operation
Configuring for Remote Programming, Sensing, and Monitoring
Revision A
53
14. Reinstall the jack screws with the nut driver.
15. Reconnect any external cables and connector.
Replacing the Cover
16. Place the cover in its original location.
17. Reinstall the eight (8) flathead Philips screws on the top of the cover, then
tighten the six (6) Philips screws in the side slots.
Powering Up
18. Reconnect the AC input connector. Turn the power supply ON.
Making J3
Connections
Some applications will use only the default factory connections on the J3 connector
located on the rear panel. Other applications will require replacing pin-to-pin
connections or making connections to external devices such as voltage sources,
current sources, or resistance. Follow the procedures in this section whenever the
rear panel connector, J3, is to be reconfigured.
The steps to follow are:
•
Dissipating stored energy
•
Making the connections
•
Powering up
Refer to the
“Dissipating Stored Energy” on page 52
and
“Powering Up” on page 53
.
Making the Connection
To make pin-to-pin connections:
1. Unsolder any pin-to-pin jumpers as required by the application.
2. Solder new connections using any appropriate single bus wire such as AWG 20
to 24.
To connect external source leads, resistance leads, or monitoring or sense lines:
3. Unsolder any jumpers as required by the application.
4. Solder leads to the specified pin using the recommended wiring and/or
grounding point for the application. Pin, wiring, and grounding specifications
for particular applications can be found in this section, except for remote sensing
specifications which are in
“Using Remote Sensing” on page 44
.
TM-25OP-01XN.book Page 53 Monday, April 5, 2004 8:58 AM
Summary of Contents for XKW 12-150
Page 2: ......
Page 3: ...Operating Manual for XKW 3000 Watt Series Programmable DC Power Supply...
Page 14: ...xii Operating Manual for XKW 3kW Series Power Supply...
Page 18: ...List of Tables xvi Operating Manual for XKW 3kW Series Power Supply...
Page 28: ...Features and Specifications Specifications 26 Operating Manual for XKW 3kW Series Power Supply...
Page 48: ...Installation Using Remote Sensing 46 Operating Manual for XKW 3kW Series Power Supply...
Page 80: ...Operation Using Multiple Supplies 78 Operating Manual for XKW 3kW Series Power Supply...
Page 89: ......