Operation
Using Multiple Supplies
74
Operating Manual for XKW 3kW Series Power Supply
Figure 3.23
Series Operation of Multiple Supplies
(Local sense lines shown are default J3 connections.)
Configuring
Multiple
Supplies for
Parallel
Operation
Parallel operation is used to obtain a higher current through a single output using two
or more supplies. Set all of the outputs to the same voltage before connecting the
positive (+) output terminals and negative (-) output terminals in parallel. See
Figure 3.23
. The total current available is the sum of the maximum currents of each
supply.
Notes:
1. Set the OVP trip level to the same point for all of the paralleled supplies.
2. When operating multiple supplies in parallel, the operating mode of each supply
will depend on the load current being drawn. For example, with two 60V-50A
output power supplies operating in parallel with a 75A load, one supply will
operate in constant current mode supplying 50A and the other supply will
operate in voltage mode supplying the remaining 25A.
POWER SUPPLY 2
POWER SUPPLY 1
POSSIBLE
AND SHORTEST LENGTH
USE THE LARGEST GAUGE
LOAD LINES
LOAD
NEGATIVE LOAD
POSITIVE LOAD
TERMINAL
TERMINAL
TERMINAL
TERMINAL
TERMINAL
TERMINAL
RETURN SENSE
RETURN SENSE
OUTPUT RETURN
OUTPUT RETURN
POSITIVE OUTPUT
POSITIVE OUTPUT
POSITIVE SENSE
POSITIVE SENSE
TM-25OP-01XN.book Page 74 Monday, April 5, 2004 8:58 AM
Summary of Contents for XKW 12-150
Page 2: ......
Page 3: ...Operating Manual for XKW 3000 Watt Series Programmable DC Power Supply...
Page 14: ...xii Operating Manual for XKW 3kW Series Power Supply...
Page 18: ...List of Tables xvi Operating Manual for XKW 3kW Series Power Supply...
Page 28: ...Features and Specifications Specifications 26 Operating Manual for XKW 3kW Series Power Supply...
Page 48: ...Installation Using Remote Sensing 46 Operating Manual for XKW 3kW Series Power Supply...
Page 80: ...Operation Using Multiple Supplies 78 Operating Manual for XKW 3kW Series Power Supply...
Page 89: ......