Installation
Installing the tunnel frame
01750058390 G
ProCash 2050xe USB - Installation Guide
147
Installation in a masonry facade:
Tighten the two adjusting bolts which
you will find on each adjusting plate
until they touch the sealing frame (see
arrow).
Installation in a glass facade:
Turn the two adjusting bolts on each
adjusting plate (see arrow) until they
are about 2 to 3 mm (0.079" to 0.12")
away from the sealing frame.
•
Unlock the operating unit, pull it out as far as possible and secure the
customer panel with a screw so that it cannot accidentally close/bang shut
(see section "Pulling out/pushing in the customer panel").
•
Secure each adjusting bolt with a corresponding nut.