Installation with 25 mm (0.98") installation frame
Installation
96
ProCash 2050xe USB - Installation Guide
01750058390 G
•
Drill the required four holes and the hole for the tear-off sensor, if
necessary (see following figures).
i
Installation on raised or cavity flooring as well as on a floating floor is
not permissible according to the CEN standard.
If the mounting structure differs from the one described below (see
illustrations below), it must be approved by the insurer.
To ensure that the safe does not become detached, the threaded rods
of the installation frame must be fastened in the concrete foundation.
The drilled holes in the concrete foundation must have a depth of at
least 125 mm (4.92") for the installation frame (see illustrations below).
For the hole diameter please refer to the mounting instructions of the
caulking cartridge.
The drilled hole in the concrete foundation must have a depth of at
least 40 mm (1.57") for the tear-off sensor (see illustrations below).
Consult your alarm technician about the size of the hole and the fixing.
Summary of Contents for ProCash 2050xe USB
Page 1: ...Installation Guide ProCash 2050xe USB Self Service Systems ...
Page 3: ...Edition June 2010 ProCash 2050xe USB Installation Guide ...
Page 18: ...Introduction 6 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 166: ...Start up Installation 154 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 200: ...Environmental protection Appendix 188 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 201: ...01750058390 G ProCash 2050xe USB Installation Guide Notes ...
Page 202: ...Published by WINCOR NIXDORF International GmbH D 33094 Paderborn Order No 01750058390 G 2 GB ...