Installation
Installation with 82 mm (3.23") installation frame
01750058390 G
ProCash 2050xe USB - Installation Guide
107
Mounting structure
CE
N
UL
(min. 1.57")
min. 40
82
(3.23")
min. 125
(min. 4.92")
*
2
4
6
7
1
3
8
5
1 Safe
5 Screed
2 Mounting set for safe
6 Concrete
3 Tear-off sensor
7 Mounting set for installation frame
4 installation frame
8 Top surface of finished floor
*
The overall drilling depth depends on the structural conditions. The
threaded rods must be anchored at least 125 mm (4.92") in the load-
bearing concrete.
Excess lengths must be shortened correspondingly or, if necessary in
case of deeper floor anchorages, be replaced by equivalent threaded
rods.
•
Clean the bore holes as specified in the mounting instructions of the
caulking cartridge.
•
Secure the threaded rods in the concrete foundation as specified in the
mounting instructions of the caulking cartridge.
i
The threaded rods must protrude at a minimum 33 mm (1.3") and at
a maximum 50 mm (1.97").
Summary of Contents for ProCash 2050xe USB
Page 1: ...Installation Guide ProCash 2050xe USB Self Service Systems ...
Page 3: ...Edition June 2010 ProCash 2050xe USB Installation Guide ...
Page 18: ...Introduction 6 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 166: ...Start up Installation 154 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 200: ...Environmental protection Appendix 188 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 201: ...01750058390 G ProCash 2050xe USB Installation Guide Notes ...
Page 202: ...Published by WINCOR NIXDORF International GmbH D 33094 Paderborn Order No 01750058390 G 2 GB ...