222 mm (8.74") installation frame
Planning the Installation
54
ProCash 2050xe USB - Installation Guide
01750058390 G
Securing the installation frame
How the installation frame is secured depends on the safe construction type
(UL, CEN L, CEN III or CEN IV).
For CEN safes, the safe construction types are distinguished in resistance
grades. The label showing the resistance level is located on the inside of the
safe door.
For a UL safe and a safe with resistance grade III (CEN III) or L (CEN L) it is
mandatory that the installation frame is secured at the points (2) with
four
threaded rods. These alternative attachment points are at position 3 (see
illustration below).
For a safe with resistance grade IV (CEN IV) it is mandatory that the CEN
frame is secured at the points (2) and (3) with
eight
threaded rods (see
illustration below).
i
If the mounting set is not provided, use equivalent fastening material.
Summary of Contents for ProCash 2050xe USB
Page 1: ...Installation Guide ProCash 2050xe USB Self Service Systems ...
Page 3: ...Edition June 2010 ProCash 2050xe USB Installation Guide ...
Page 18: ...Introduction 6 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 166: ...Start up Installation 154 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 200: ...Environmental protection Appendix 188 ProCash 2050xe USB Installation Guide 01750058390 G ...
Page 201: ...01750058390 G ProCash 2050xe USB Installation Guide Notes ...
Page 202: ...Published by WINCOR NIXDORF International GmbH D 33094 Paderborn Order No 01750058390 G 2 GB ...