Appendix
Technical data
01750058390 G
ProCash 2050xe USB - Installation Guide
179
110 - 120 V
220 - 240 V
Idle
mode
Operation
(max.)
Idle mode Operation
(max.)
Heating (without device)
Rated current
consumption:
5.4
A
2.9
A
Apparent power
consumption:
700
VA
650
VA
Active power:
700 W
650 W
Protection class:
Ι
Ι
Type of device connection
(wall outlet): *
Country-specific safety
plug
Country-specific safety
plug
CEE plug in acc. with
IEC 309
CEE plug in acc. with
IEC 309
Fuse protection:
10 A slow-blow fuse or
16 A circuit-breaker
10 A slow-blow fuse or
16 A circuit-breaker
Degree of protection in
acc. with EN 60529:
Outdoors:
IP
54
IP
54
Indoors:
IP
20
IP
20
* If a UPS is used, it must be connected with a CEE plug only.